IM-05 Insulation monitoring relay
  • IM-05 Insulation monitoring relay
  • IM-05 Insulation monitoring relay
  • IM-05 Insulation monitoring relay
  • IM-05 Insulation monitoring relay

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: Trafox

IM-05 Insulation monitoring relay

Insulation monitoring relay dedicated to electric vehicles, charging stations and DC drives.

Specification:

Monitored circuit

AC voltage range 0…690V
DC voltage range 0…1000V
frequency range DC, 10…500Hz

Power

DC range: 10..36V

Enables monitoring

  • Insulation resistance between HV circuit and earth
  • The correctness of the earth connection
  • System voltage
  • Auto-Test

Range of default alarm settings

Insulation resistance response value Ran 100kΩ...1MOhm
Hysteresis of reaction to change of insulation resistance 25 %
Undervoltage detection threshold OFF / 50…500V
Averaging factor 1…10

Measurement specification

Resistance measurement range 0kΩ…10MΩ
measurement error ±20kΩ @ 0…50 kΩ
±15% @ 50kΩ... 2MΩ
±25% @ 2MΩ…10MΩ
UM voltage measurement ±25V
IM current measurement for RF = 0 50uA
Impedance Zi at 50 Hz ≥ 500kΩ
Internal DC resistance Ri ≥ 500kΩ
System leakage capacitance Ce (nominal value) ≤ 1uF
Response time tan (RF = 10 MΩ to Ran/2; at Ce < 1 μF) 5s
Response time tan (RF = 10 MΩ to Ran/2; at Ce < 2 μF) 10s
Response time tan (RF = 10 MΩ to Ran/2; at Ce < 3 μF) 15s

other details

Operating temperature range -40…+85°C
Operating humidity range (max.) 95% bez kondensacji
Mounting Śruby metalowe M4
Max dimension - height 25mm
Max dimension - width 60mm
Max dimension - length 140mm
Weight 100g

Standards

Measurement IEC 61557-8:2014 (requires an alarm indicator with a test button in the installation)
Security IEC 61010-1:2010 (3rd Edition), IEC 60664-1
Safety of electric vehicles ISO 6469-3:2021
Road vehicles - environmental conditions and tests for electrical and electronic devices ISO 16750-1, ISO 16750-2, ISO 16750-3
Environmental tests IEC 60068-2-14, IEC 60068-2-27, IEC 60068-2-30, IEC 60068-2-38, IEC 60068-2-64

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Insulation monitoring relay dedicated to electric vehicles, charging stations and DC drives.

Specification:

Monitored circuit

AC voltage range 0…690V
DC voltage range 0…1000V
frequency range DC, 10…500Hz

Power

DC range: 10..36V

Enables monitoring

  • Insulation resistance between HV circuit and earth
  • The correctness of the earth connection
  • System voltage
  • Auto-Test

Range of default alarm settings

Insulation resistance response value Ran 100kΩ...1MOhm
Hysteresis of reaction to change of insulation resistance 25 %
Undervoltage detection threshold OFF / 50…500V
Averaging factor 1…10

Measurement specification

Resistance measurement range 0kΩ…10MΩ
measurement error ±20kΩ @ 0…50 kΩ
±15% @ 50kΩ... 2MΩ
±25% @ 2MΩ…10MΩ
UM voltage measurement ±25V
IM current measurement for RF = 0 50uA
Impedance Zi at 50 Hz ≥ 500kΩ
Internal DC resistance Ri ≥ 500kΩ
System leakage capacitance Ce (nominal value) ≤ 1uF
Response time tan (RF = 10 MΩ to Ran/2; at Ce < 1 μF) 5s
Response time tan (RF = 10 MΩ to Ran/2; at Ce < 2 μF) 10s
Response time tan (RF = 10 MΩ to Ran/2; at Ce < 3 μF) 15s

other details

Operating temperature range -40…+85°C
Operating humidity range (max.) 95% bez kondensacji
Mounting Śruby metalowe M4
Max dimension - height 25mm
Max dimension - width 60mm
Max dimension - length 140mm
Weight 100g

Standards

Measurement IEC 61557-8:2014 (requires an alarm indicator with a test button in the installation)
Security IEC 61010-1:2010 (3rd Edition), IEC 60664-1
Safety of electric vehicles ISO 6469-3:2021
Road vehicles - environmental conditions and tests for electrical and electronic devices ISO 16750-1, ISO 16750-2, ISO 16750-3
Environmental tests IEC 60068-2-14, IEC 60068-2-27, IEC 60068-2-30, IEC 60068-2-38, IEC 60068-2-64