BM197 Clamp Meter 2000A AC / DC TRMS, VFD, USB, CAT IV 1000V
BM197 Clamp Meter 2000A AC / DC TRMS, VFD, USB, CAT IV 1000V

Photos are for informational purposes only. View product specification

please use latin characters

BM197 Clamp Meter 2000A AC / DC TRMS, VFD, USB, CAT IV 1000V

BM197 Clamp meter 2000A AC/DC TRMS,VFD,USB, CAT IV 1000V

Technical Data
Special Features and Special Functions
  • Clamp-on measurement:
    • Maximum cable diameter:
      • 55mm
  • True RMS - True RMS measurement
  • Automatic/manual measurement range switching
  • Temperature measurement
  • DATA HOLD - freezes the current measurement result on the display
  • Hz - simultaneous display of frequency and measured voltage or current
  • - on a dual display
  • RELATIVE ZERO - differential measurement from the measured value
  • CREST: recording of MAX and MIN peak pulse values:
    • ongoing >5ms, V and A only
  • EF: Non-contact electric field (voltage) detection
  • Safe measurements in Cat. IV
  • Diode and continuity tests (with audible signal)
  • PC communication via RS-232 optical port
  • PC communication via USB interface
  • VFD (ACV[&]Hz) - simultaneous measurement of inverter voltage and frequency
  • Lo-Z - low-impedance voltage measurements (interference elimination)
  • AutoCheck - automatic selection of measurement type (Lo-Z DCV, ACV,
    resistance) depending on the input signal


Measurements and Accuracy
  • Temperature Coefficient:
    • Nominal 0.15 x (specified accuracy)/°C
      (-10°C to 18°C ​​or 28°C to 55°C)
  • Accuracy:
    • +- (% of the displayed value + number of least significant digits), unless otherwise specified,
      for a temperature of 23°C +- 5° and RH < 75%
Continuity Test
Min. Detection Range R [Ω] Max. Detection Range R [Ω] DC Peak Protection [V] Protection ACrms [V]
10 200 1000 1000

Response time:
  • < 32ms


DCV - constant voltage
Range [V] Resolution [V] Accuracy [%] Accuracy [digits] Input imp. [Ω] Input imp. [F] DCpeak [V] protection ACrms protection [V]
6 0.001 0.5 5 10M 50p 1000 1000
  • The input impedance increases above 50V and is: 10kΩ for 100V, 60kΩ for 300V, 200kΩ for 600V, 420kΩ for 1000V.
  • The LoZ DCV input impedance is initially approximately 2.5kΩ, 600pF nominal.
  • DCV threshold impedance >+1.5VDC or < -1.5VDC


ACV - Alternating Voltage
5 1000
Range [V] Resolution [V] Accuracy [%] Accuracy [digits] Min. Frequency [Hz] Max. Frequency [Hz] Input Impedance [Ω] Input Impedance [F] DC Peak Protection [V] DC Peak Protection ACrms [V]
6 0.001 1,2 5 50 400 10M 50p 1000 1000
60 0.01 1,2 5 50 400 10M 50p 1000 1000
600 0.1 1,2 5 50 400 10M 50p 1000 1000
1000 1 1,2 5 50 400 10M 50p 1000 1000
6 (Autocheck) 0.001 1.5 5 50 60 2.5k 600p 1000 1000
60 (Autocheck) 0.01 1.5 50 60 2.5k 600p 1000 1000
60 (Autocheck) 0.01 1.5 5 50 60 2.5k 600p 1000 1000
600 (Autocheck) 0.1 1.5 5 50 60 2.5k 600p 1000 1000
1000 (Autocheck) 1 1.5 5 50 60 2.5k 600p 1000 1000
6 (VFD) 0.001 4 80 10 20 1000 1000
60 (VFD) 0.01 4 80 10 20 1000 1000
600 (VFD) 0.1 4 80 10 20 1000 1000
1000 (VFD) 1 4 80 10 20 1000 1000
6 (VFD) 0.001 2 60 20 200 1000 1000
60 (VFD) 0.01 2 60 20 200 1000 1000
600 (VFD) 0.1 2 60 20 200 1000 1000
1000 (VFD) 1 2 60 20 200 1000 1000
6 (VFD) 0.001 7 80 200 400 1000 1000
60 (VFD) 0.01 7 80 200 400 1000
600 (VFD) 0.1 7 80 200 400 1000 1000
1000 (VFD) 1 7 80 200 400 1000 1000
  • Crest Factor:
    • CF < 2.8:1 at full scale
    • CF < 1.4:1 at mid-scale
  • In VFD_ACV mode, accuracy drops from 2% + 50d at 200Hz to 7% + 80d at 400Hz.
  • In AutoCheck mode, the input impedance increases above 50V and is: 10kΩ for 100V, 60kΩ for 300V, 200kΩ for 600V, 420kΩ for 1000V.
  • The LoZ ACV input impedance in AutoCheck mode is initially approximately 2.5kΩ, 600pF nominal.
  • LoZ ACV impedance threshold > 1.5V (50/60Hz)
  • TrueRMS


DCV+ACV Voltage
Range [V] Resolution [V] Accuracy [%] Accuracy [digits] Min. Frequency [Hz] Max. Frequency [Hz] Input Impedance [Ω] Input Impedance [F] DC Peak Protection [V] DC Peak Protection ACrms [V]
6 0.001 1.4 7 50 400 10M 50p 1000 1000
60 0.01 1.4 7 50 400 10M 50p 1000 1000
600 0.1 1.4 7 50 400 10M 50p 1000 1000
1000 1 1.4 7 50 400 10M 50p 1000 1000
  • Crest factor:
    • CF < 2.8:1 half scale
    • CF < 1.4:1 full scale
  • TrueRMS


DCA - Direct Current
5
Range [A] Resolution [A] Accuracy [%] [digit] accuracy Fuse [A]
200 0.1 2.0 2000
0~500 1 2.0 5 2000
500~2000 1 3.0 5 2000
  • Additional error in the presence of current-carrying conductors near the clamps
  • DCA current clamp measurement
  • Accuracy determined in relative measurement mode, after zeroing the reading for a current-free state.


ACA - alternating current
1 1000~2000
Range [A] Resolution [A] Accuracy [%] Accuracy [digits] Min. frequency [Hz] Max. frequency [Hz] Fuse [A]
200 0.1 2.5 5 40 50 2000
0~500 1 3.0 5 40 50 2000
500~1000 1 3.5 5 40 50 2000
1000~2000 1 40 50 2000
200 0.1 2.0 5 50 60 2000
0~500 1 2.5 5 50 60 2000
500~2000 3.0 5 50 60 2000
200 0.1 2.5 5 60 400 2000
0~500 1 3.0 5 60 400 2000
500~1000 1 3.5 5 60 400 2000
1 60 400 2000
  • ACA Current Clamp Measurement
  • Additional error in the presence of current-carrying conductors near the clamps < 0.1A/A
  • TrueRMS
  • Crest Factor:
    • CF
    • CF


DCA+ACA Current
Range [A] Resolution [A] Accuracy [%] Accuracy [digits] Min. frequency [Hz] Max. frequency [Hz]
200 0.1 3.5 8 40 50
0~1000 1 3.5 8 40 50
1000~2000 1 40 50
200 0.1 3.0 8 50 60
2000 1 3.0 8 50 60
200 0.1 3.5 8 60 400
0~1000 1 3.5 8 60 400
1000~200 1 60 400
      • Crest Factor:
        • CF < 2.8:1 half scale
        • CF < 1.4:1 at full scale
      • Clamp current measurement DCA+ACA
      • Accuracy determined in relative measurement mode, after zeroing the reading for a current-free state.
      • Additional error in the presence of current-carrying conductors near the clamps
      • TrueRMS


Resistance
Range [Ω] Resolution [Ω] Accuracy [%] Accuracy [digits] Open Circuit Voltage [V] DC Peak Protection [V] ACrms Protection [V]
600 0.1 0.5 5 0.45 1000 1000
6k 0.001k 0.5 5 0.45 1000 1000
60k 0.01k

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

BM197 Clamp meter 2000A AC/DC TRMS,VFD,USB, CAT IV 1000V

Technical Data
Special Features and Special Functions
  • Clamp-on measurement:
    • Maximum cable diameter:
      • 55mm
  • True RMS - True RMS measurement
  • Automatic/manual measurement range switching
  • Temperature measurement
  • DATA HOLD - freezes the current measurement result on the display
  • Hz - simultaneous display of frequency and measured voltage or current
  • - on a dual display
  • RELATIVE ZERO - differential measurement from the measured value
  • CREST: recording of MAX and MIN peak pulse values:
    • ongoing >5ms, V and A only
  • EF: Non-contact electric field (voltage) detection
  • Safe measurements in Cat. IV
  • Diode and continuity tests (with audible signal)
  • PC communication via RS-232 optical port
  • PC communication via USB interface
  • VFD (ACV[&]Hz) - simultaneous measurement of inverter voltage and frequency
  • Lo-Z - low-impedance voltage measurements (interference elimination)
  • AutoCheck - automatic selection of measurement type (Lo-Z DCV, ACV,
    resistance) depending on the input signal


Measurements and Accuracy
  • Temperature Coefficient:
    • Nominal 0.15 x (specified accuracy)/°C
      (-10°C to 18°C ​​or 28°C to 55°C)
  • Accuracy:
    • +- (% of the displayed value + number of least significant digits), unless otherwise specified,
      for a temperature of 23°C +- 5° and RH < 75%
Continuity Test
Min. Detection Range R [Ω] Max. Detection Range R [Ω] DC Peak Protection [V] Protection ACrms [V]
10 200 1000 1000

Response time:
  • < 32ms


DCV - constant voltage
Range [V] Resolution [V] Accuracy [%] Accuracy [digits] Input imp. [Ω] Input imp. [F] DCpeak [V] protection ACrms protection [V]
6 0.001 0.5 5 10M 50p 1000 1000
  • The input impedance increases above 50V and is: 10kΩ for 100V, 60kΩ for 300V, 200kΩ for 600V, 420kΩ for 1000V.
  • The LoZ DCV input impedance is initially approximately 2.5kΩ, 600pF nominal.
  • DCV threshold impedance >+1.5VDC or < -1.5VDC


ACV - Alternating Voltage
5 1000
Range [V] Resolution [V] Accuracy [%] Accuracy [digits] Min. Frequency [Hz] Max. Frequency [Hz] Input Impedance [Ω] Input Impedance [F] DC Peak Protection [V] DC Peak Protection ACrms [V]
6 0.001 1,2 5 50 400 10M 50p 1000 1000
60 0.01 1,2 5 50 400 10M 50p 1000 1000
600 0.1 1,2 5 50 400 10M 50p 1000 1000
1000 1 1,2 5 50 400 10M 50p 1000 1000
6 (Autocheck) 0.001 1.5 5 50 60 2.5k 600p 1000 1000
60 (Autocheck) 0.01 1.5 50 60 2.5k 600p 1000 1000
60 (Autocheck) 0.01 1.5 5 50 60 2.5k 600p 1000 1000
600 (Autocheck) 0.1 1.5 5 50 60 2.5k 600p 1000 1000
1000 (Autocheck) 1 1.5 5 50 60 2.5k 600p 1000 1000
6 (VFD) 0.001 4 80 10 20 1000 1000
60 (VFD) 0.01 4 80 10 20 1000 1000
600 (VFD) 0.1 4 80 10 20 1000 1000
1000 (VFD) 1 4 80 10 20 1000 1000
6 (VFD) 0.001 2 60 20 200 1000 1000
60 (VFD) 0.01 2 60 20 200 1000 1000
600 (VFD) 0.1 2 60 20 200 1000 1000
1000 (VFD) 1 2 60 20 200 1000 1000
6 (VFD) 0.001 7 80 200 400 1000 1000
60 (VFD) 0.01 7 80 200 400 1000
600 (VFD) 0.1 7 80 200 400 1000 1000
1000 (VFD) 1 7 80 200 400 1000 1000
  • Crest Factor:
    • CF < 2.8:1 at full scale
    • CF < 1.4:1 at mid-scale
  • In VFD_ACV mode, accuracy drops from 2% + 50d at 200Hz to 7% + 80d at 400Hz.
  • In AutoCheck mode, the input impedance increases above 50V and is: 10kΩ for 100V, 60kΩ for 300V, 200kΩ for 600V, 420kΩ for 1000V.
  • The LoZ ACV input impedance in AutoCheck mode is initially approximately 2.5kΩ, 600pF nominal.
  • LoZ ACV impedance threshold > 1.5V (50/60Hz)
  • TrueRMS


DCV+ACV Voltage
Range [V] Resolution [V] Accuracy [%] Accuracy [digits] Min. Frequency [Hz] Max. Frequency [Hz] Input Impedance [Ω] Input Impedance [F] DC Peak Protection [V] DC Peak Protection ACrms [V]
6 0.001 1.4 7 50 400 10M 50p 1000 1000
60 0.01 1.4 7 50 400 10M 50p 1000 1000
600 0.1 1.4 7 50 400 10M 50p 1000 1000
1000 1 1.4 7 50 400 10M 50p 1000 1000
  • Crest factor:
    • CF < 2.8:1 half scale
    • CF < 1.4:1 full scale
  • TrueRMS


DCA - Direct Current
5
Range [A] Resolution [A] Accuracy [%] [digit] accuracy Fuse [A]
200 0.1 2.0 2000
0~500 1 2.0 5 2000
500~2000 1 3.0 5 2000
  • Additional error in the presence of current-carrying conductors near the clamps
  • DCA current clamp measurement
  • Accuracy determined in relative measurement mode, after zeroing the reading for a current-free state.


ACA - alternating current
1 1000~2000
Range [A] Resolution [A] Accuracy [%] Accuracy [digits] Min. frequency [Hz] Max. frequency [Hz] Fuse [A]
200 0.1 2.5 5 40 50 2000
0~500 1 3.0 5 40 50 2000
500~1000 1 3.5 5 40 50 2000
1000~2000 1 40 50 2000
200 0.1 2.0 5 50 60 2000
0~500 1 2.5 5 50 60 2000
500~2000 3.0 5 50 60 2000
200 0.1 2.5 5 60 400 2000
0~500 1 3.0 5 60 400 2000
500~1000 1 3.5 5 60 400 2000
1 60 400 2000
  • ACA Current Clamp Measurement
  • Additional error in the presence of current-carrying conductors near the clamps < 0.1A/A
  • TrueRMS
  • Crest Factor:
    • CF
    • CF


DCA+ACA Current
Range [A] Resolution [A] Accuracy [%] Accuracy [digits] Min. frequency [Hz] Max. frequency [Hz]
200 0.1 3.5 8 40 50
0~1000 1 3.5 8 40 50
1000~2000 1 40 50
200 0.1 3.0 8 50 60
2000 1 3.0 8 50 60
200 0.1 3.5 8 60 400
0~1000 1 3.5 8 60 400
1000~200 1 60 400
      • Crest Factor:
        • CF < 2.8:1 half scale
        • CF < 1.4:1 at full scale
      • Clamp current measurement DCA+ACA
      • Accuracy determined in relative measurement mode, after zeroing the reading for a current-free state.
      • Additional error in the presence of current-carrying conductors near the clamps
      • TrueRMS


Resistance
Range [Ω] Resolution [Ω] Accuracy [%] Accuracy [digits] Open Circuit Voltage [V] DC Peak Protection [V] ACrms Protection [V]
600 0.1 0.5 5 0.45 1000 1000
6k 0.001k 0.5 5 0.45 1000 1000
60k 0.01k
Comments (0)