SW31K-AC690V - Voltage Monitor for 3-phase Networks - S222271
SW31K-AC690V - Voltage Monitor for 3-phase Networks - S222271
SW31K-AC690V - Voltage Monitor for 3-phase Networks - S222271

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: ZIEHL

SW31K-AC690V - Voltage Monitor for 3-phase Networks - S222271

  • S222271
  • Product Type IP00 motor, IP20 electronics
  • Supply voltage AC 230 V
  • Execution Motor IP44, electronics IP20 / depending on mounting and position
  • Output function Outputs/Relays
  • Measured value Pressed, painted steel sheet, sprayed with PP plastic

Undervoltage monitor for threephase networks without N for monitoring on voltage failure. The voltage is being measured between phases and an artificial neutral point. At symmetrical decrease of the voltage to approx. 50% of the nominal value or in case of failure of a phase the integrated relay (1 change-over contact) releases with a delay ofapprox. 1s. With engines running on 2 phases, so much back voltage can be produced that the failure of a phase may be not detected. The SW31K is available for measuring voltages AC 400 V and AC 690 V. As supply voltage in the standard version AC 230 V is needed.

Application

  • Monitoring of three-phase networks on loss of a phase
  • monitoring of fuses

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

  • Product Type IP00 motor, IP20 electronics
  • Supply voltage AC 230 V
  • Execution Motor IP44, electronics IP20 / depending on mounting and position
  • Output function Outputs/Relays
  • Measured value Pressed, painted steel sheet, sprayed with PP plastic

Undervoltage monitor for threephase networks without N for monitoring on voltage failure. The voltage is being measured between phases and an artificial neutral point. At symmetrical decrease of the voltage to approx. 50% of the nominal value or in case of failure of a phase the integrated relay (1 change-over contact) releases with a delay ofapprox. 1s. With engines running on 2 phases, so much back voltage can be produced that the failure of a phase may be not detected. The SW31K is available for measuring voltages AC 400 V and AC 690 V. As supply voltage in the standard version AC 230 V is needed.

Application

  • Monitoring of three-phase networks on loss of a phase
  • monitoring of fuses
Comments (0)