EVR600 DC Relay
  • EVR600 DC Relay

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: YM Tech

EVR600 DC Relay

  • EVR600

Application

  • Battery Energy Storage System
  • Electric Vehicle,
  • Charging System,
  • Solar System,
  • Golf Car
  • Fuel Cell Vehicle
  • etc.

Magnet coil ratings

Nominal voltage(V)Inrush Coil current 100ms (Max.)Holding Coil current (A)Pick-up voltage (V)MaxDrop-out voltage (V)MinHolding voltage (V)Min.Max. voltage (V)Max.
B 72 1.3A 0.045~0.07A 32VDC 18VDC 22VDC 95VDC
60
36
A 36 3.8A 0.11A 9VDC 6VDC 7.5VDC 36VDC
24 0.16A
12 0.32A
12 1.2A 0.32A 9VDC 6VDC 7.5VDC 18VDC
24 0.6A 0.16A 18VDC 12VDC 13.5VDC 32VDC

Contact ratings

Type1Pole Resistive load (L/R≤1㎳)
Max. Continuous current (wire size 185㎟×2) 600A
Max. switching current 600A
Max. switching voltages 900VDC
Contact Rating switching voltages 12~900VDC
Voltage drop across contacts per 100A 30mV Max.
Min. permissible load 12VDC 0.5A
Description S.P On/Off (a)
Contact Arrangement, auxiliary contacts 1Form A (SPST-NO.)
General Aux. Contact Current, Max. 2A 30VDC / 3A 125VAC
General Aux. Contact Current, Min. 100mA 8VDC
Gold alloy Aux. Contacts Max. 0.1A 30VDC / 0.1A 30VAC
Gold alloy Aux. Contacts Min. 1mA 5VDC / 1mA 5VAC

Characteristics

Expected lifeMechanical (Min.)2×106
Electric (L/R≤1㎳) 450V DC 600A 1×103
250V DC 600A 1×105
Initial insulation resistance Min. 100㏁ 500V DC
Initial breakdown voltage Between open contacts 3500V AC 60 Sec. 5mA
Between contacts & coil 3500V AC 60 Sec. 5mA
Operate time (at 20℃) Max. 30㎳
Release time (at 20℃) Max. 10㎳
Shock resistance Functional Min 196 ㎨ {20G}
Destructive Min 490 ㎨ {50G}
Vibration resistance Functional 100 ㎨ {20G} 80 to 2000㎐
Destructive 100 ㎨ {20G} 80 to 2000㎐
Conditions for operation transport and storage Ambient temperature -40℃ to +85℃
Humidity 5 to 85% R.H.
Unit weight 920g

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Application

  • Battery Energy Storage System
  • Electric Vehicle,
  • Charging System,
  • Solar System,
  • Golf Car
  • Fuel Cell Vehicle
  • etc.

Magnet coil ratings

Nominal voltage(V)Inrush Coil current 100ms (Max.)Holding Coil current (A)Pick-up voltage (V)MaxDrop-out voltage (V)MinHolding voltage (V)Min.Max. voltage (V)Max.
B 72 1.3A 0.045~0.07A 32VDC 18VDC 22VDC 95VDC
60
36
A 36 3.8A 0.11A 9VDC 6VDC 7.5VDC 36VDC
24 0.16A
12 0.32A
12 1.2A 0.32A 9VDC 6VDC 7.5VDC 18VDC
24 0.6A 0.16A 18VDC 12VDC 13.5VDC 32VDC

Contact ratings

Type1Pole Resistive load (L/R≤1㎳)
Max. Continuous current (wire size 185㎟×2) 600A
Max. switching current 600A
Max. switching voltages 900VDC
Contact Rating switching voltages 12~900VDC
Voltage drop across contacts per 100A 30mV Max.
Min. permissible load 12VDC 0.5A
Description S.P On/Off (a)
Contact Arrangement, auxiliary contacts 1Form A (SPST-NO.)
General Aux. Contact Current, Max. 2A 30VDC / 3A 125VAC
General Aux. Contact Current, Min. 100mA 8VDC
Gold alloy Aux. Contacts Max. 0.1A 30VDC / 0.1A 30VAC
Gold alloy Aux. Contacts Min. 1mA 5VDC / 1mA 5VAC

Characteristics

Expected lifeMechanical (Min.)2×106
Electric (L/R≤1㎳) 450V DC 600A 1×103
250V DC 600A 1×105
Initial insulation resistance Min. 100㏁ 500V DC
Initial breakdown voltage Between open contacts 3500V AC 60 Sec. 5mA
Between contacts & coil 3500V AC 60 Sec. 5mA
Operate time (at 20℃) Max. 30㎳
Release time (at 20℃) Max. 10㎳
Shock resistance Functional Min 196 ㎨ {20G}
Destructive Min 490 ㎨ {50G}
Vibration resistance Functional 100 ㎨ {20G} 80 to 2000㎐
Destructive 100 ㎨ {20G} 80 to 2000㎐
Conditions for operation transport and storage Ambient temperature -40℃ to +85℃
Humidity 5 to 85% R.H.
Unit weight 920g