Plant room double thermostat RTKSA
  • Plant room double thermostat RTKSA

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: ALRE

Plant room double thermostat RTKSA

Application

RTKSA plant room thermostats were specially developed for use in industrial halls, exhibition halls, air halls and greenhouses. When used as a frost protection controller, the higher tolerances at the end of the scale must be observed. 2 separate setting ranges, heating and/or cooling.

Technical data

Color: Anthracite grey (similar to RAL 7016), front side transparent
Sensor material: V4A
Max. sensor temperature Top scale value +15%
Max. head temperature: 50 °C
Permissible atmospheric humidity: Max. 95% rel. humidity, non-condensing
Operating voltage: none
Max. switching current: NC contact:
16 (2.5) A at 230 VAC +10%
0.25 A at 230 VDC +10%
NO contact:
6.3 (2.5) A at 230 VAC +10%
0.25 A at 230 VDC +10%
Min. switching current: Min. 100 mA at 24 V (AC/DC)
Max. switching voltage: 230 VAC 50/60 Hz, 230 VDC
Min. switching voltage: 24 VAC/50 Hz, 24 VDC
Switching element: microswitch
Switching contact: 2 x togglers, potential-free
Control function: Heating or cooling, heating and cooling
Hysteresis: 1.3 K
Electrical connection: Push-in terminals
Mounting/attachment: wall mounting
Protection class: I
Protection rating: IP 54 (optionally IP 65)
Safety and EMC: In accordance with DIN EN 60730 (VDE 0631)
Sensor: liquid-filled capillary
General features: Scale: degrees Celsius

Type testing by TÜV in accordance with DIN EN 14597

Type Item no. 1st Control range 2nd Control range Features PG
RTKSA-114.110 KA011100 0…+50 °C (TW, internal) 0…+50 °C (TW, internal) 2 x internal setting II
RTKSA-114.010 KA011101 −10…+40 °C (TW, internal) −10…+40 °C (TW, internal) 2 x internal setting II

Type comparison (old/new type)

Old alre types Control range Hysteresis New alre types Control range Hysteresis
JET-30 10…45 °C (external) TR
0 ...35 °C (internal) TW
approx. 1 K RTKSA-114.110 0…+50 °C (internal) TW
0…+50 °C (internal) TW
1.3 K
JET-31 10…+45 °C (internal) TW
0…+35 °C (internal) TW
approx. 1 K

TR = temperature controller, TW = temperature monitor

Type testing by TÜV in accordance with DIN EN 14597

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Application

RTKSA plant room thermostats were specially developed for use in industrial halls, exhibition halls, air halls and greenhouses. When used as a frost protection controller, the higher tolerances at the end of the scale must be observed. 2 separate setting ranges, heating and/or cooling.

Technical data

Color: Anthracite grey (similar to RAL 7016), front side transparent
Sensor material: V4A
Max. sensor temperature Top scale value +15%
Max. head temperature: 50 °C
Permissible atmospheric humidity: Max. 95% rel. humidity, non-condensing
Operating voltage: none
Max. switching current: NC contact:
16 (2.5) A at 230 VAC +10%
0.25 A at 230 VDC +10%
NO contact:
6.3 (2.5) A at 230 VAC +10%
0.25 A at 230 VDC +10%
Min. switching current: Min. 100 mA at 24 V (AC/DC)
Max. switching voltage: 230 VAC 50/60 Hz, 230 VDC
Min. switching voltage: 24 VAC/50 Hz, 24 VDC
Switching element: microswitch
Switching contact: 2 x togglers, potential-free
Control function: Heating or cooling, heating and cooling
Hysteresis: 1.3 K
Electrical connection: Push-in terminals
Mounting/attachment: wall mounting
Protection class: I
Protection rating: IP 54 (optionally IP 65)
Safety and EMC: In accordance with DIN EN 60730 (VDE 0631)
Sensor: liquid-filled capillary
General features: Scale: degrees Celsius

Type testing by TÜV in accordance with DIN EN 14597

Type Item no. 1st Control range 2nd Control range Features PG
RTKSA-114.110 KA011100 0…+50 °C (TW, internal) 0…+50 °C (TW, internal) 2 x internal setting II
RTKSA-114.010 KA011101 −10…+40 °C (TW, internal) −10…+40 °C (TW, internal) 2 x internal setting II

Type comparison (old/new type)

Old alre types Control range Hysteresis New alre types Control range Hysteresis
JET-30 10…45 °C (external) TR
0 ...35 °C (internal) TW
approx. 1 K RTKSA-114.110 0…+50 °C (internal) TW
0…+50 °C (internal) TW
1.3 K
JET-31 10…+45 °C (internal) TW
0…+35 °C (internal) TW
approx. 1 K

TR = temperature controller, TW = temperature monitor

Type testing by TÜV in accordance with DIN EN 14597