Busbar passing measuring CT’s TAC053
  • Busbar passing measuring CT’s TAC053

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: FRER

TAC053 current transformer for Ø40 cables on a rail 51x32mm and 41x41mm

Technical Data

Thermoplastic material UL94-V0
Operating frequency 50-60Hz
Voltage 0.72kV
Test voltage 3kV * 1’50Hz
Insulation Klasa E
Protection degree IP 20
Continuous overcurrent 1,2In
Rated short-time thermal current (I th) 60 In
Rated dynamic current (I dyn) 2.5 x I th
Safety factor N<5
max. power dissipation (max range value) <20W
Operating temperature -25 +50o C
Storage temperature -40 +80o C
Manufactured according to

IEC/E N 60044-1,
VDE, BS, UTE

 

SECONDARY 5A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1
200/5 A 2 4

TAC053200X05

250/5 A 4 8

TAC053250X05

300/5 A 5 10

TAC053300X05

400/5 A 6 12

TAC053400X05

500/5 A 10 20

TAC053500X05

600/5 A 15 25

TAC053600X05

800/5 A 20 30

TAC053800X05

1000/5 A 30 40

TAC0531K0X05

1200/5 A 30 40

TAC0531K2X05

1500/5 A 30 40

TAC0531K5X05

SECONDARY 1A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1
200/1 A 2 4

TAC053200X01

250/1 A 4 8

TAC053250X01

300/1 A 5 10

TAC053300X01

400/1 A 6 12

TAC053400X01

500/1 A 10 20

TAC053500X01

600/1 A 15 25

TAC053600X01

800/1 A 20 30

TAC053800X01

1000/1 A 30 40

TAC0531K0X01

1200/1 A 30 40

TAC0531K2X01

1500/1 A 30 40

TAC0531K5X01

2000/1 A 30 40

TAC0532K0X01

 

Dimensions

Przekładnik prądowy TAC053

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Technical Data

Thermoplastic material UL94-V0
Operating frequency 50-60Hz
Voltage 0.72kV
Test voltage 3kV * 1’50Hz
Insulation Klasa E
Protection degree IP 20
Continuous overcurrent 1,2In
Rated short-time thermal current (I th) 60 In
Rated dynamic current (I dyn) 2.5 x I th
Safety factor N<5
max. power dissipation (max range value) <20W
Operating temperature -25 +50o C
Storage temperature -40 +80o C
Manufactured according to

IEC/E N 60044-1,
VDE, BS, UTE

 

SECONDARY 5A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1
200/5 A 2 4

TAC053200X05

250/5 A 4 8

TAC053250X05

300/5 A 5 10

TAC053300X05

400/5 A 6 12

TAC053400X05

500/5 A 10 20

TAC053500X05

600/5 A 15 25

TAC053600X05

800/5 A 20 30

TAC053800X05

1000/5 A 30 40

TAC0531K0X05

1200/5 A 30 40

TAC0531K2X05

1500/5 A 30 40

TAC0531K5X05

SECONDARY 1A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1
200/1 A 2 4

TAC053200X01

250/1 A 4 8

TAC053250X01

300/1 A 5 10

TAC053300X01

400/1 A 6 12

TAC053400X01

500/1 A 10 20

TAC053500X01

600/1 A 15 25

TAC053600X01

800/1 A 20 30

TAC053800X01

1000/1 A 30 40

TAC0531K0X01

1200/1 A 30 40

TAC0531K2X01

1500/1 A 30 40

TAC0531K5X01

2000/1 A 30 40

TAC0532K0X01

 

Dimensions

Przekładnik prądowy TAC053