Busbar passing measuring CT’s TAT128
  • Busbar passing measuring CT’s TAT128

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: FRER

TAT128 current transformer for a 127x85mm rail

Technical Data

Thermoplastic material UL94-V0
Operating frequency 50-60Hz
Voltage 0.72kV
Test voltage 3kV * 1’50Hz
Insulation Klasa E
Protection degree IP 20
Continuous overcurrent 1.2In
Rated short-time thermal current (I th) 80 In
Rated dynamic current (I dyn) 2.5 x I th
Safety factor N<5
max. power dissipation (max range value) <40W
Operating temperature -25 +50o C
Storage temperature -40 +80o C
Manufactured according to

IEC/E N 60044-1,
VDE, BS, UTE

 

SECONDARY 5A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1
1000/5 A 25 50

TAT1281K0X05

1200/5 A 30 60

TAT1281K2X05

1500/5 A 35 70

TAT1281K5X05

2000/5 A 40 80

TAT1282K0X05

2500/5 A 50 100

TAT1282K5X05

3000/5 A 70 120

TAT1283K0X05

4000/5 A 80 150

TAT1284K0X05

5000/5 A 100 180

TAT1285K0X05

SECONDARY 1A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1
1000/1 A 25 50

TAT1281K0X01

1200/1 A 30 60

TAT1281K2X01

1500/1 A 35 70

TAT1281K5X01

2000/1 A 40 80

TAT1282K0X01

2500/1 A 50 100

TAT1282K5X01

3000/1 A 70 120

TAT1283K0X01

4000/1 A 80 150

TAT1284K0X01

5000/1 A 100 180

TAT1285K0X01

 

Dimensions

Przekładnik prądowy TAT128 na szynę 127x85mm

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Technical Data

Thermoplastic material UL94-V0
Operating frequency 50-60Hz
Voltage 0.72kV
Test voltage 3kV * 1’50Hz
Insulation Klasa E
Protection degree IP 20
Continuous overcurrent 1.2In
Rated short-time thermal current (I th) 80 In
Rated dynamic current (I dyn) 2.5 x I th
Safety factor N<5
max. power dissipation (max range value) <40W
Operating temperature -25 +50o C
Storage temperature -40 +80o C
Manufactured according to

IEC/E N 60044-1,
VDE, BS, UTE

 

SECONDARY 5A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1
1000/5 A 25 50

TAT1281K0X05

1200/5 A 30 60

TAT1281K2X05

1500/5 A 35 70

TAT1281K5X05

2000/5 A 40 80

TAT1282K0X05

2500/5 A 50 100

TAT1282K5X05

3000/5 A 70 120

TAT1283K0X05

4000/5 A 80 150

TAT1284K0X05

5000/5 A 100 180

TAT1285K0X05

SECONDARY 1A

Ratio Burdens
[VA]
Code
cl. 0.5 cl. 1
1000/1 A 25 50

TAT1281K0X01

1200/1 A 30 60

TAT1281K2X01

1500/1 A 35 70

TAT1281K5X01

2000/1 A 40 80

TAT1282K0X01

2500/1 A 50 100

TAT1282K5X01

3000/1 A 70 120

TAT1283K0X01

4000/1 A 80 150

TAT1284K0X01

5000/1 A 100 180

TAT1285K0X01

 

Dimensions

Przekładnik prądowy TAT128 na szynę 127x85mm