GEA-20/35P(D) series
  • GEA-20/35P(D) series

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: GINICE KOREA

Electric Linear actuator GEA-20 / 35P9 (D)


Features:

  • Proportional or On-Off Electric Linear Actuator
  • Self-Calibration using the auto setting button
  • Visual FND display using digit, applied to GEA-20/35PD
  • Minimized maintenance due to the durable structure and reliable operating
  • Valve is closed or stop automatically in case input signal is removed or failed.
  • Manual override with handle-wheel
  • Selectable input signal 4~20mA , 0-10VDC or 2-10VDC
  • Applied into Heating, Ventilation, Air conditioning or Ice thermal storage system


Technical data

Item GEA-20P(D) GEA-35P(D)
Nominal Stroke (mm) 20mm  40mm
Nominal Force (KN) 2000N (2.0)  3500N (3.5) 
Operating Time (Sec) 50sec (0.4mm/s)  100sec (0.4mm/s)
Power Supply (V) 24VAC or 220VAC ± 10%  24VAC or 220VAC ± 10% 
Operating mode Modulating or On-Off Modulating or On-Off
Input Signal 4~20mA, 0-10VDC lub 2-10VDC  4~20mA, 0-10VDC lub 2-10VDC 
Output Signal Same as input signal Same as input signal
Operation Temperature -15 ~ 60℃ -15 ~ 60℃
Humidity 5 ~ 95% Rh 5 ~ 95% Rh
Enclosure IP 54 (DIN4050)  IP 54 (DIN4050) 
Conduit Entries PF1/2x 2EA  PF1/2x 2EA 
Net Weight (Kg) 3.4Kg  3.5Kg 

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in


Features:

  • Proportional or On-Off Electric Linear Actuator
  • Self-Calibration using the auto setting button
  • Visual FND display using digit, applied to GEA-20/35PD
  • Minimized maintenance due to the durable structure and reliable operating
  • Valve is closed or stop automatically in case input signal is removed or failed.
  • Manual override with handle-wheel
  • Selectable input signal 4~20mA , 0-10VDC or 2-10VDC
  • Applied into Heating, Ventilation, Air conditioning or Ice thermal storage system


Technical data

Item GEA-20P(D) GEA-35P(D)
Nominal Stroke (mm) 20mm  40mm
Nominal Force (KN) 2000N (2.0)  3500N (3.5) 
Operating Time (Sec) 50sec (0.4mm/s)  100sec (0.4mm/s)
Power Supply (V) 24VAC or 220VAC ± 10%  24VAC or 220VAC ± 10% 
Operating mode Modulating or On-Off Modulating or On-Off
Input Signal 4~20mA, 0-10VDC lub 2-10VDC  4~20mA, 0-10VDC lub 2-10VDC 
Output Signal Same as input signal Same as input signal
Operation Temperature -15 ~ 60℃ -15 ~ 60℃
Humidity 5 ~ 95% Rh 5 ~ 95% Rh
Enclosure IP 54 (DIN4050)  IP 54 (DIN4050) 
Conduit Entries PF1/2x 2EA  PF1/2x 2EA 
Net Weight (Kg) 3.4Kg  3.5Kg