J2130A – Bloker Biasu
  • J2130A – Bloker Biasu

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: Picotest

J2130A - Bialy blocker

J2130A – Bloker Biasu

When using the network analyzer to measure impedance, such as the capacitance and ESR or a capacitor, or the DCR of an inductor, etc., it is often necessary to provide a voltage bias to the device being tested. This is true of semiconductor junction capacitances, varactors, and some ceramic capacitors (especially X5R). In these cases the impedance is a function of the DC bias on the device. The Picotest DC bias injector (J2130A) is used for this purpose during impedance measurements.

 

Key features:

  • 10Hz-10MHz usable bandwidth
  • Low loss design
  • Easily measure varactors, junction capacitance
  • Measure X5R capacitor voltage sensitivity
  • Bias low power transistor amplifiers and diodes for parameter extraction

Rated data:

Maximum DC Bias 50V
Bias Resistance 10kΩ
Maximum Bias Current 5mA
Frequency Response 15Hz…40MHz
Temperature range 0…50°C
Maximum Altitude 1850m
Absolute Maximum Differential Voltage <50V DC
Absolute Maximum Voltage <50V AC and 75V DC

 

Connection diagram:

J2130A – Bloker Biasu schemat łączeniowy

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

J2130A – Bloker Biasu

When using the network analyzer to measure impedance, such as the capacitance and ESR or a capacitor, or the DCR of an inductor, etc., it is often necessary to provide a voltage bias to the device being tested. This is true of semiconductor junction capacitances, varactors, and some ceramic capacitors (especially X5R). In these cases the impedance is a function of the DC bias on the device. The Picotest DC bias injector (J2130A) is used for this purpose during impedance measurements.

 

Key features:

  • 10Hz-10MHz usable bandwidth
  • Low loss design
  • Easily measure varactors, junction capacitance
  • Measure X5R capacitor voltage sensitivity
  • Bias low power transistor amplifiers and diodes for parameter extraction

Rated data:

Maximum DC Bias 50V
Bias Resistance 10kΩ
Maximum Bias Current 5mA
Frequency Response 15Hz…40MHz
Temperature range 0…50°C
Maximum Altitude 1850m
Absolute Maximum Differential Voltage <50V DC
Absolute Maximum Voltage <50V AC and 75V DC

 

Connection diagram:

J2130A – Bloker Biasu schemat łączeniowy