BackX
-
All categories
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Transducers for Protection, Monitoring and Control | LEM
- Split-core Transducers | LEM
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Drivers and Panels
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
SERVICE, REPAIRS
-
-
Installation of equipment
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Recorder KR3000 series
KR3000 Series are network-compatible paperless recorders with high performance and high operating function employed high visibility 12.1” TFT color LCD display and touch panel operation system. High speed of sampling rate 100ms for 48 points and high accuracy of ±0.1% were realized, and measured data is stored into internal memory and maximum 2GB compact flash card (CF card). As it can be monitored by a web browser display on several computers on intranet or internet, FTP transfer of data file and E-mail notification are also available.
Technical data
Measuring points | 12, 24, 36 or 48 points |
Input: DC voltage |
±13.8 mV, ±27.6 mV, ±69.0 mV, ±200 mV, ±500 mV, ±2 V, ±5 V*, ±10 V*, ±20 V*, ±50 V* (*with built-in voltage divider) |
Input: DC current |
External shunt resistor (sold separately) |
Input: Thermocouples |
B, R, S, K, E, J, T, N, PtRh40-PtRh20,W-WRe26, WRe5-WRe26, Platinum, NiMo-Ni, CR-AuFe, U, L |
Input: Resistive sensor |
Pt100, JPt100, Pt50, Pt-Co |
Sampling period | 100 ms --- approx. 100 ms for all points |
1 s --- approx. 300 ms for all points | |
Internal memory |
136 MB |
Additional memory |
CF card (up to 2 GB) |
Register cycle |
100, 200, 500 ms |
1, 2, 3, 5, 10, 15, 20, 30 s | |
1, 2, 3, 5, 10, 15, 20, 30, 60 min | |
Alarm setup |
4 alarms per channel |
Alarm types |
Upper limit, lower limit, differential upper limit, differential lower limit (deadband is selectable), abnormal data |
Alarm delay |
1 do 3600 s |
Alarm settings |
AND/OR |
Display | 12.1” TFT color LCD |
Display types |
Measured data screen - real-time and historical trends, bargraphs, data screen, alarm screen, information screen, setting screen |
Communication types |
Ethernet (10BASE-T / 100BASE-TX) |
FTP server | Data file can be read from the network computer |
FTP client |
Transfer a data file to a network server |
SNTP client | The time can be synchronized to the time of SNTP server |
Web server | Conformed to HTTP1.0 --- Display the alarm, information of maintenance by browser software (InternetExplorer 5.0 or later, NetScape 6.0 or later, Opera 7 or later) |
E-Mail notification at specified time for alarm activation | |
Report data at specified time is selectable from all registered data | |
Notification address --- max. 8 contacts | |
USB | USB 2.0 |
Power supply | 100...240 VAC, 50/60Hz |
Max. power consumption |
65 VA |
Ambient temperature | 0 - 50 °C |
Ambient humidity |
20 - 80%RH |
Weight | 7.2 kg |
Mounting | Panel mouting |
Connection
Dimensions [mm]
Product number
Measuring points/sampling rate
|
Communications interface (option)
|
Digital input/alarm output (option)
|
|||
20: 12 points/100ms
40: 24 points/100ms 60: 36 points/100ms 80: 48 points/100ms 21: 12 points/1s 41: 24 points/1s 61: 36 points/1s 81: 48 points/1s |
N: None
R: High-order (RS232C) S: High-order (RS422A/RS485) |
0: None
1: Alarm output 12 points (a contact) 2: Alarm output 6 points (c contact) 3: Alarm output 24 points (a contact) 4: Alarm output 12 points (c contact) 5: Alarm output 12 points (a contact) + 6 points (c contact) A: Digital input 8 points B: Digital input 8 points + alarm output 12 points (a contact) C: Digital input 8 points + alarm output 6 points (c contact) D: Digital input 8 points + alarm output 24 points (a contact) E: Digital input 8 points + alarm output 12 points (c contact) F: Digital input 8 points + alarm output 12 points (a contact) + alarm output 6 points (c contact) |
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Recorder KR3000 series
KR3000 Series are network-compatible paperless recorders with high performance and high operating function employed high visibility 12.1” TFT color LCD display and touch panel operation system. High speed of sampling rate 100ms for 48 points and high accuracy of ±0.1% were realized, and measured data is stored into internal memory and maximum 2GB compact flash card (CF card). As it can be monitored by a web browser display on several computers on intranet or internet, FTP transfer of data file and E-mail notification are also available.
Technical data
Measuring points | 12, 24, 36 or 48 points |
Input: DC voltage |
±13.8 mV, ±27.6 mV, ±69.0 mV, ±200 mV, ±500 mV, ±2 V, ±5 V*, ±10 V*, ±20 V*, ±50 V* (*with built-in voltage divider) |
Input: DC current |
External shunt resistor (sold separately) |
Input: Thermocouples |
B, R, S, K, E, J, T, N, PtRh40-PtRh20,W-WRe26, WRe5-WRe26, Platinum, NiMo-Ni, CR-AuFe, U, L |
Input: Resistive sensor |
Pt100, JPt100, Pt50, Pt-Co |
Sampling period | 100 ms --- approx. 100 ms for all points |
1 s --- approx. 300 ms for all points | |
Internal memory |
136 MB |
Additional memory |
CF card (up to 2 GB) |
Register cycle |
100, 200, 500 ms |
1, 2, 3, 5, 10, 15, 20, 30 s | |
1, 2, 3, 5, 10, 15, 20, 30, 60 min | |
Alarm setup |
4 alarms per channel |
Alarm types |
Upper limit, lower limit, differential upper limit, differential lower limit (deadband is selectable), abnormal data |
Alarm delay |
1 do 3600 s |
Alarm settings |
AND/OR |
Display | 12.1” TFT color LCD |
Display types |
Measured data screen - real-time and historical trends, bargraphs, data screen, alarm screen, information screen, setting screen |
Communication types |
Ethernet (10BASE-T / 100BASE-TX) |
FTP server | Data file can be read from the network computer |
FTP client |
Transfer a data file to a network server |
SNTP client | The time can be synchronized to the time of SNTP server |
Web server | Conformed to HTTP1.0 --- Display the alarm, information of maintenance by browser software (InternetExplorer 5.0 or later, NetScape 6.0 or later, Opera 7 or later) |
E-Mail notification at specified time for alarm activation | |
Report data at specified time is selectable from all registered data | |
Notification address --- max. 8 contacts | |
USB | USB 2.0 |
Power supply | 100...240 VAC, 50/60Hz |
Max. power consumption |
65 VA |
Ambient temperature | 0 - 50 °C |
Ambient humidity |
20 - 80%RH |
Weight | 7.2 kg |
Mounting | Panel mouting |
Connection
Dimensions [mm]
Product number
Measuring points/sampling rate
|
Communications interface (option)
|
Digital input/alarm output (option)
|
|||
20: 12 points/100ms
40: 24 points/100ms 60: 36 points/100ms 80: 48 points/100ms 21: 12 points/1s 41: 24 points/1s 61: 36 points/1s 81: 48 points/1s |
N: None
R: High-order (RS232C) S: High-order (RS422A/RS485) |
0: None
1: Alarm output 12 points (a contact) 2: Alarm output 6 points (c contact) 3: Alarm output 24 points (a contact) 4: Alarm output 12 points (c contact) 5: Alarm output 12 points (a contact) + 6 points (c contact) A: Digital input 8 points B: Digital input 8 points + alarm output 12 points (a contact) C: Digital input 8 points + alarm output 6 points (c contact) D: Digital input 8 points + alarm output 24 points (a contact) E: Digital input 8 points + alarm output 12 points (c contact) F: Digital input 8 points + alarm output 12 points (a contact) + alarm output 6 points (c contact) |