AT 100 B10 current transducer

  • AT 100 B10
  • Accuracy 1,50%
  • Rated Current [A] 100
  • Primary signal [AC / AC+DC / DC] AC
  • Supply voltage [V] Not required
  • Mounting [THT / SMD / DIN / Panel / On primary rail] On the primary bus
  • App Automation/Renewable Energy/Drives
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -20
  • Maximum operating temperature [°C] 60
  • Frequency response (-3dB) [kHz] 0,06
  • Feedback loop [open / closed] // Eta technology Current transformer

Applications:

  • Automation and Monitoring
    Current measurement for process control via distributed PLC or remote control (e.g., SCADA software).
  • Safety and Condition Monitoring
    Load monitoring for protection and predictive maintenance systems (e.g., conveyors, pumps, or HVAC motors).

Technical Data:

Measured quantity Current
Rated current 100A
Measuring range 100A
Output signal DC RMS voltage 0-10V
Signal Primary AC
Power Supply Not Required
Accuracy 1.5%
Operating Temperature -20°C…60°C
Technology Current Transformer
Mounting On Primary Busbar
396.06 PLN
396.06 PLN Gross price / pcs.
322.00 PLN Net price / pc.
Tax included

Availability: Please be advised that this product is out of stock

You can place a pre-order, report your interest in the product by clicking the "Ask for availability" button.

Out of stock
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

  • Accuracy 1,50%
  • Rated Current [A] 100
  • Primary signal [AC / AC+DC / DC] AC
  • Supply voltage [V] Not required
  • Mounting [THT / SMD / DIN / Panel / On primary rail] On the primary bus
  • App Automation/Renewable Energy/Drives
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -20
  • Maximum operating temperature [°C] 60
  • Frequency response (-3dB) [kHz] 0,06
  • Feedback loop [open / closed] // Eta technology Current transformer

Applications:

  • Automation and Monitoring
    Current measurement for process control via distributed PLC or remote control (e.g., SCADA software).
  • Safety and Condition Monitoring
    Load monitoring for protection and predictive maintenance systems (e.g., conveyors, pumps, or HVAC motors).

Technical Data:

Measured quantity Current
Rated current 100A
Measuring range 100A
Output signal DC RMS voltage 0-10V
Signal Primary AC
Power Supply Not Required
Accuracy 1.5%
Operating Temperature -20°C…60°C
Technology Current Transformer