AT 150 B420L current transducer
AT 150 B420L current transducer

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: LEM

AT 150 B420L current transducer

  • AT 150 B420L
  • Accuracy 1,50%
  • Rated Current [A] 150
  • Primary signal [AC / AC+DC / DC] AC
  • Supply voltage [V] Loop powered
  • Mounting [THT / SMD / DIN / Panel / On primary rail] On the primary bus
  • App Automation/Renewable Energy/Drives
  • Output signal type [current/voltage] current
  • Minimum operating temperature [°C] -20
  • Maximum operating temperature [°C] 60
  • Frequency response (-3dB) [kHz] 0,06
  • Feedback loop [open / closed] // Eta technology Current transformer

Applications:

  • Automation and Monitoring
    Current measurement for process control via distributed PLC or remote control (e.g., SCADA software).
  • Safety and Condition Monitoring
    Load monitoring for protection systems and predictive maintenance (e.g., conveyors, pumps, or HVAC motors).
  • Energy Management
    Convenient connection to energy submeters.

Technical Data:

Measured quantity Current
Rated current 150A
Measuring range 150A
Output signal DC RMS current 4-20mA
Signal Primary AC
Power Supply Not Required
Accuracy 1.5%
Operating Temperature -20°C…60°C
Technology Current Transformer
Mounting On Primary Busbar
568.26 PLN
568.26 PLN Gross price / pcs.
462.00 PLN Net price / pc.
Tax included

Availability: Please be advised that this product is out of stock

You can place a pre-order, report your interest in the product by clicking the "Ask for availability" button.

Out of stock
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

  • Accuracy 1,50%
  • Rated Current [A] 150
  • Primary signal [AC / AC+DC / DC] AC
  • Supply voltage [V] Loop powered
  • Mounting [THT / SMD / DIN / Panel / On primary rail] On the primary bus
  • App Automation/Renewable Energy/Drives
  • Output signal type [current/voltage] current
  • Minimum operating temperature [°C] -20
  • Maximum operating temperature [°C] 60
  • Frequency response (-3dB) [kHz] 0,06
  • Feedback loop [open / closed] // Eta technology Current transformer

Applications:

  • Automation and Monitoring
    Current measurement for process control via distributed PLC or remote control (e.g., SCADA software).
  • Safety and Condition Monitoring
    Load monitoring for protection systems and predictive maintenance (e.g., conveyors, pumps, or HVAC motors).
  • Energy Management
    Convenient connection to energy submeters.

Technical Data:

Measured quantity Current
Rated current 150A
Measuring range 150A
Output signal DC RMS current 4-20mA
Signal Primary AC
Power Supply Not Required
Accuracy 1.5%
Operating Temperature -20°C…60°C
Technology Current Transformer
Mounting On Primary Busbar
Comments (0)