  • AT 20 B10
  • Accuracy 1,50%
  • Rated Current [A] 20
  • Primary signal [AC / AC+DC / DC] AC
  • Supply voltage [V] Not required
  • Mounting [THT / SMD / DIN / Panel / On primary rail] On the primary bus
  • App Automation/Renewable Energy/Drives
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -20
  • Maximum operating temperature [°C] 60
  • Frequency response (-3dB) [kHz] 0,06
  • Feedback loop [open / closed] // Eta technology Current transformer

Applications:

  • Automation and Monitoring
    Current measurement for process control via distributed PLC or remote control (e.g., SCADA software).
  • Safety and Condition Monitoring
    Load monitoring for protection and predictive maintenance systems (e.g., conveyors, pumps, or HVAC motors).

Technical Data:

Measured quantity Current
Rated current 20A
Measuring range 20A
Output signal DC RMS voltage 0-10V
Signal Primary AC
Power Supply Not Required
Accuracy 1.5%
Operating Temperature -20°C…60°C
Technology Current Transformer
Mounting On Primary Busbar
302.58 PLN
302.58 PLN Gross price / pcs.
246.00 PLN Net price / pc.
Tax included
Availability: Available quantity: 6
1 - 2 Business Days Estimated delivery / order fulfillment time. The order fulfillment time depends on the production capabilities.
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

  • Accuracy 1,50%
  • Rated Current [A] 20
  • Primary signal [AC / AC+DC / DC] AC
  • Supply voltage [V] Not required
  • Mounting [THT / SMD / DIN / Panel / On primary rail] On the primary bus
  • App Automation/Renewable Energy/Drives
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -20
  • Maximum operating temperature [°C] 60
  • Frequency response (-3dB) [kHz] 0,06
  • Feedback loop [open / closed] // Eta technology Current transformer

Applications:

  • Automation and Monitoring
    Current measurement for process control via distributed PLC or remote control (e.g., SCADA software).
  • Safety and Condition Monitoring
    Load monitoring for protection and predictive maintenance systems (e.g., conveyors, pumps, or HVAC motors).

Technical Data:

Measured quantity Current
Rated current 20A
Measuring range 20A
Output signal DC RMS voltage 0-10V
Signal Primary AC
Power Supply Not Required
Accuracy 1.5%
Operating Temperature -20°C…60°C
Technology Current Transformer
Mounting On Primary Busbar