Designed for electronic current measurement: DC, AC, pulsed, etc., with galvanic isolation between the primary and secondary circuits.
Main Features| Parameter | Value |
|---|---|
| Rated Primary Current | 50A |
| Measuring Range Primary Current | -150…150A |
| Supply Voltage | 5V |
| Output Voltage | 0÷5V |
| Output Voltage for Primary Current Ip=0 | 2.5V |
| Theoretical Sensitivity | 41.67 mV/A |
| Sensitivity Error | -0.7÷0.7% |
| Offset Voltage Electrical | -7.1÷7.1mV |
| Electrical offset current with respect to primary current | -0.17÷0.17A |
| Maximum supply voltage | 7V |
| Maximum primary conductor temperature | 110°C |
| Maximum primary conductor current | 20xIpn |
| Maximum discharge voltage | 4kV |
| Maximum temperature ambient | 85°C |
Availability: Please be advised that this product is out of stock
You can place a pre-order, report your interest in the product by clicking the "Ask for availability" button.
Designed for electronic current measurement: DC, AC, pulsed, etc., with galvanic isolation between the primary and secondary circuits.
Main Features| Parameter | Value |
|---|---|
| Rated Primary Current | 50A |
| Measuring Range Primary Current | -150…150A |
| Supply Voltage | 5V |
| Output Voltage | 0÷5V |
| Output Voltage for Primary Current Ip=0 | 2.5V |
| Theoretical Sensitivity | 41.67 mV/A |
| Sensitivity Error | -0.7÷0.7% |
| Offset Voltage Electrical | -7.1÷7.1mV |
| Electrical offset current with respect to primary current | -0.17÷0.17A |
| Maximum supply voltage | 7V |
| Maximum primary conductor temperature | 110°C |
| Maximum primary conductor current | 20xIpn |
| Maximum discharge voltage | 4kV |
| Maximum temperature ambient | 85°C |