LTC 600-S current transducer
LTC 600-S current transducer

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: LEM

LTC 600-S current transducer

  • LTC 600-S
  • Accuracy 0,70%
  • Rated Current [A] 500
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] 15...24V DC
  • Mounting [THT / SMD / DIN / Panel / On primary rail] Panel
  • App Automation/Drives/Renewable Energy/Power Supplies
  • Output signal type [current/voltage] current
  • Minimum operating temperature [°C] -40
  • Maximum operating temperature [°C] 85
  • Frequency response (-3dB) [kHz] 100
  • Feedback loop [open / closed] // Eta technology closed

Applications:

  • Single-phase or three-phase inverters
  • Choppers for driving and braking
  • Drive converters
  • Auxiliary converters
  • Battery chargers

Technical data:

Rated current 500A
Measuring range ±1500A
Output signal Current, ±100mA
Primary Signal AC+DC
Power Supply 15…24V DC
Accuracy 0.7%
Operating Temperature -40°C…85°C
Technology Closed feedback loop, the phenomenon Halla
Mounting Panel
1,081.17 PLN
1,081.17 PLN Gross price / pcs.
879.00 PLN Net price / pc.
Tax included

Availability: Please be advised that this product is out of stock

You can place a pre-order, report your interest in the product by clicking the "Ask for availability" button.

Out of stock
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

  • Accuracy 0,70%
  • Rated Current [A] 500
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] 15...24V DC
  • Mounting [THT / SMD / DIN / Panel / On primary rail] Panel
  • App Automation/Drives/Renewable Energy/Power Supplies
  • Output signal type [current/voltage] current
  • Minimum operating temperature [°C] -40
  • Maximum operating temperature [°C] 85
  • Frequency response (-3dB) [kHz] 100
  • Feedback loop [open / closed] // Eta technology closed

Applications:

  • Single-phase or three-phase inverters
  • Choppers for driving and braking
  • Drive converters
  • Auxiliary converters
  • Battery chargers

Technical data:

Rated current 500A
Measuring range ±1500A
Output signal Current, ±100mA
Primary Signal AC+DC
Power Supply 15…24V DC
Accuracy 0.7%
Operating Temperature -40°C…85°C
Technology Closed feedback loop, the phenomenon Halla
Mounting Panel
Comments (0)