FMCW Radar Level Transmitter
FMCW Radar Level Transmitter

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: FineTek

FMCW Radar Level Transmitter

The FMCW radar level transmitter is a non-contact measuring device that is suitable for applications in high temperature, high pressure and corrosive environments. It is easy to install and requires no maintenance, especially in environments requiring high accuracy.

Main Features:

  • Non-contact measurement
  • Measurement of corrosive substances, toxic liquids, hydrocarbons, and slurries
  • Unaffected by specific gravity, pressure, temperature, viscosity, or foam
  • 5-digit LCD display
  • Indicates the signal waveform inside the silo
  • Selection of various measurement units (m, cm, mm, inch, Ft, %, mA)
  • Distance and actual level measurement
  • Language selection: Traditional Chinese, Simplified Chinese, English
  • Output: 4-20 mA / 4-wire / 2-wire
  • Modbus RS-485 for increased isolation and ease of remote control
  • CE standards for isolation (EFT 2000V, Class B or better)
  • Suitable for medium-range signal
  • Isolated circuit design

Applications:

  • Chemical industry
  • Petrochemical industry
  • Pharmaceutical industry
  • Food industry
Dimensions [mm] Finetek
Model JFR-204 JFR-214
Medium Typical Liquids Typical Liquids / Suitable for Acids and Bases in Liquids
Minimum Dielectric Constant (Liquid) 1.4
Measuring range 30m
Accuracy ±3mm
Repeatability ±1mm
Digital communication RS485 (isolated)
Ambient temperature -40…80°C (LCM<75°C)
Operating temperature -40…200°C
Operating pressure 0…40 bar
Frequency K-band
Analog output 4…20mA / 4-wire
Protection class IP67
Supply voltage 9.5…30V DC
Local Display LCM, 5-digit
Housing Material Aluminum
Antenna Type Horn (43D) Lens (56D)
Half Power Angle ±9°
Antenna Material SUS316+PTFE PTFE
Minimum distance of the sensor from the liquid 500mm

Typical Liquids
Dimensions [mm] jfr-244 jfr234 jfr244
Model JFR-224 JFR-234 JFR-244
Medium
Min. Dielectric Constant (Liquid) 1.4
Measuring Range 40m 70m 20m
Accuracy ±3mm at a distance ≤30m
±0.01% F.S. for distance >30m
±3mm
Repeatability ±1mm
Digital communication RS485 (isolated)
Ambient temperature -40…80°C (LCM<75°C)
Operating temperature -40…200°C
Pressure Operating Pressure 0…40 bar
Frequency K Band
Analog Output 4…20mA / 4-Wire
Protection Rating IP67
Supply Voltage 9.5…30V DC
Local Display LCM, 5-digit
Housing Material Aluminum
Antenna Type High Gain Horn (100) High Gain Horn (140) Lens (43DS)
Half Power Angle ±5° ±3° ±10°
Material SUS 316 PTFE
Minimum distance of the sensor from the liquid 500mm

Dimensions [mm] jfr-202 jfr-212
Model JFR-202 JFR-212
Medium Typical Liquids Typical Liquids / Suitable for Acids and Bases in Liquids
Minimum Dielectric Constant (Liquid) 1.4
Range Measurement 20m
Accuracy ±5mm
Repeatability ±3mm
Digital Communication HART
Ambient Temperature -40…80°C (LCM<75°C)
Operating Temperature -40…200°C
Working pressure 0…40 bar
Frequency K-band
Analog output 4…20mA
Protection class IP67
Supply voltage 24V DC ±10%
Local Display LCM, 5-digit
Housing Material Aluminum
Antenna Type Horn (43D) Lens (56D)
Half Power Angle ±9°
Material SUS 316+PTFE PTFE
Minimum Distance liquid sensor 500mm

Dimensions [mm] jfr-222 jfr-232 jfr-242
Model JFR-222 JFR-232 JFR-242
Medium Typical Liquids
Intended Use Long Distance Measurement Very Long Distance Measurement Measurement of Corrosive Acidic and Alkaline Liquids
Minimum Dielectric Constant (Liquid) 1.4
Measuring Range 30m 35m 15m
Accuracy ±5mm at a distance of ≤20m
±0.025% F.S. for distance >20m
±5mm
Repeatability ±3mm
Digital communication HART
Ambient temperature -40…80°C (LCM<75°C)
Operating temperature -40…200°C
Operating pressure 0…40 bar
Frequency K-Band
Analog Output 4…20mA
Protection Rating IP67
Supply Voltage 24V DC ± 10%
Local Display LCM, 5-digit
Housing Material Aluminum
Antenna Type High Gain Horn (100) High Gain Horn (140) Lens (43DS)
Half Power Angle ±5° ±3° ±10°
Antenna Material SUS 316 PTFE
Minimum sensor distance from liquid 500mm

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

The FMCW radar level transmitter is a non-contact measuring device that is suitable for applications in high temperature, high pressure and corrosive environments. It is easy to install and requires no maintenance, especially in environments requiring high accuracy.

Main Features:

  • Non-contact measurement
  • Measurement of corrosive substances, toxic liquids, hydrocarbons, and slurries
  • Unaffected by specific gravity, pressure, temperature, viscosity, or foam
  • 5-digit LCD display
  • Indicates the signal waveform inside the silo
  • Selection of various measurement units (m, cm, mm, inch, Ft, %, mA)
  • Distance and actual level measurement
  • Language selection: Traditional Chinese, Simplified Chinese, English
  • Output: 4-20 mA / 4-wire / 2-wire
  • Modbus RS-485 for increased isolation and ease of remote control
  • CE standards for isolation (EFT 2000V, Class B or better)
  • Suitable for medium-range signal
  • Isolated circuit design

Applications:

  • Chemical industry
  • Petrochemical industry
  • Pharmaceutical industry
  • Food industry
Dimensions [mm] Finetek
Model JFR-204 JFR-214
Medium Typical Liquids Typical Liquids / Suitable for Acids and Bases in Liquids
Minimum Dielectric Constant (Liquid) 1.4
Measuring range 30m
Accuracy ±3mm
Repeatability ±1mm
Digital communication RS485 (isolated)
Ambient temperature -40…80°C (LCM<75°C)
Operating temperature -40…200°C
Operating pressure 0…40 bar
Frequency K-band
Analog output 4…20mA / 4-wire
Protection class IP67
Supply voltage 9.5…30V DC
Local Display LCM, 5-digit
Housing Material Aluminum
Antenna Type Horn (43D) Lens (56D)
Half Power Angle ±9°
Antenna Material SUS316+PTFE PTFE
Minimum distance of the sensor from the liquid 500mm

Typical Liquids
Dimensions [mm] jfr-244 jfr234 jfr244
Model JFR-224 JFR-234 JFR-244
Medium
Min. Dielectric Constant (Liquid) 1.4
Measuring Range 40m 70m 20m
Accuracy ±3mm at a distance ≤30m
±0.01% F.S. for distance >30m
±3mm
Repeatability ±1mm
Digital communication RS485 (isolated)
Ambient temperature -40…80°C (LCM<75°C)
Operating temperature -40…200°C
Pressure Operating Pressure 0…40 bar
Frequency K Band
Analog Output 4…20mA / 4-Wire
Protection Rating IP67
Supply Voltage 9.5…30V DC
Local Display LCM, 5-digit
Housing Material Aluminum
Antenna Type High Gain Horn (100) High Gain Horn (140) Lens (43DS)
Half Power Angle ±5° ±3° ±10°
Material SUS 316 PTFE
Minimum distance of the sensor from the liquid 500mm

Dimensions [mm] jfr-202 jfr-212
Model JFR-202 JFR-212
Medium Typical Liquids Typical Liquids / Suitable for Acids and Bases in Liquids
Minimum Dielectric Constant (Liquid) 1.4
Range Measurement 20m
Accuracy ±5mm
Repeatability ±3mm
Digital Communication HART
Ambient Temperature -40…80°C (LCM<75°C)
Operating Temperature -40…200°C
Working pressure 0…40 bar
Frequency K-band
Analog output 4…20mA
Protection class IP67
Supply voltage 24V DC ±10%
Local Display LCM, 5-digit
Housing Material Aluminum
Antenna Type Horn (43D) Lens (56D)
Half Power Angle ±9°
Material SUS 316+PTFE PTFE
Minimum Distance liquid sensor 500mm

Dimensions [mm] jfr-222 jfr-232 jfr-242
Model JFR-222 JFR-232 JFR-242
Medium Typical Liquids
Intended Use Long Distance Measurement Very Long Distance Measurement Measurement of Corrosive Acidic and Alkaline Liquids
Minimum Dielectric Constant (Liquid) 1.4
Measuring Range 30m 35m 15m
Accuracy ±5mm at a distance of ≤20m
±0.025% F.S. for distance >20m
±5mm
Repeatability ±3mm
Digital communication HART
Ambient temperature -40…80°C (LCM<75°C)
Operating temperature -40…200°C
Operating pressure 0…40 bar
Frequency K-Band
Analog Output 4…20mA
Protection Rating IP67
Supply Voltage 24V DC ± 10%
Local Display LCM, 5-digit
Housing Material Aluminum
Antenna Type High Gain Horn (100) High Gain Horn (140) Lens (43DS)
Half Power Angle ±5° ±3° ±10°
Antenna Material SUS 316 PTFE
Minimum sensor distance from liquid 500mm
Comments (0)