Category
Photos are for informational purposes only. View product specification
please use latin characters
Typical Applications:
Certificates:



Features:
Flameproof protection made of high-quality brass with an IP rating of: IP66 + IP67 + IP68(5bar) + IP69K. For indoor and outdoor use, Zone 1, Zone 2, Zone 21, and Zone 22 hazardous areas, protecting all types of cables in sealed LTP conduits. Brass gland with nylon seal and two-part epoxy resin.
| Size | Name | Thread size | Dimensions [mm] | ||||
|---|---|---|---|---|---|---|---|
| A | B | C | D (A/F) | E (A/F) | F (I/D) | ||
| 16 |
LTP16-M20-EXD |
M20x1.5 | 15 | 32 | 29 | 30 | 10.7 |
LTP20-M20-EXD |
M20x1.5 | 15 | 32 | 29 | 30 | 13.0 | |
| 25 |
LTP25-M25-EXD |
M25x1.5 | 15 | 35 | 35 | 36 | 18.0 |
| 32 |
LTP32-M32-EXD |
M32x1.5 | 15 | 37 | 42 | 46 | 24.0 |
| 40 |
LTP40-M40-EXD |
M40x1.5 | 15 | 38 | 52 | 52 | 30.4 |
| 50 |
LTP50-M50-EXD |
M50x1.5 | 15 | 40 | 58 | 60 | 37.0 |
| 63 |
LTP63-M63-EXD |
M63x1.5 | 15 | 40 | 70 | 70 | |
Features:
Flameproof protection made of high-quality brass with an IP rating of: IP66 + IP67 + IP68(5bar) + IP69K. Suitable for indoor and outdoor use, Zone 1, Zone 2, Zone 21, and Zone 22 hazardous areas, protecting all types of cables in sealed LTP conduits. Brass gland with nylon seal and two-part epoxy resin.
| Size | Name | NTP thread size | Dimensions [mm] | ||||
|---|---|---|---|---|---|---|---|
| A | B | C | D (A/F) | E (A/F) | F (I/D) | ||
| 16 |
LTP16-050-EXD |
½” | 20 | 32 | 29 | 30 | 10.7 |
LTP20-050-EXD |
½” | 20 | 32 | 29 | 30 | 13.0 | |
| 25 |
LTP25-075-EXD |
¾” | 20 | 35 | 35 | 36 | 18.0 |
| 32 |
LTP32-100-EXD |
1" | 25 | 37 | 42 | 46 | 24.0 |
| 40 |
LTP40-125-EXD |
1 ¼” | 26 | 52 | 52 | 30.4 | |
| 50 |
LTP50-150-EXD |
1 ½” | 26 | 40 | 58 | 60 | 37.0 |
| 63 |
LTP63-200-EXD |
2” | 15 | 40 | 70 | 70 | 48.4 |
Features:
Flameproof protection made of high-quality stainless steel (316) with an IP rating of IP66 + IP67 + IP68(5bar) + IP69K. For indoor and outdoor use, Zone 1, Zone 2, Zone 21, and Zone 22 hazardous areas, protecting all types of cables in sealed LTP conduits. Stainless steel (316) cable gland with a nylon seal and two-part epoxy resin. NTP thread version available upon request.
| Size | Name | Thread size | Dimensions [mm] | ||||
|---|---|---|---|---|---|---|---|
| A | B | C | D (A/F) | E (A/F) | F (I/D) | ||
| 20 |
LTP20-M20-EXD-SS |
M20x1.5 | 15 | 32 | 29 | 30 | 13.0 |
| 25 |
LTP25-M25-EXD-SS |
15 | 35 | 35 | 36 | 18.0 | |
| 32 |
LTP32-M32-EXD-SS |
M32x1.5 | 15 | 37 | 42 | 46 | 24.0 |
| 40 |
LTP40-M40-EXD-SS |
M40x1.5 | 15 | 38 | 52 | 30.4 | |
| 50 |
LTP50-M50-EXD-SS |
M50x1.5 | 15 | 40 | 58 | 60 | 37.0 |
| 63 |
LTP63-M63-EXD-SS |
M63x1.5 | 15 | 40 | 70 | 70 | 48.4 |
| ATEX APPROVAL to EN60079-0 2009 | |
| Ex d Flameproof | Ex d I Mb EN 60079-1 2007 |
| Ex d Flameproof | Ex d II C Gb EN 60079-1 2007 |
| Ex e Increased Safety | Ex e I Mb EN 60079-7 2007 |
| Ex e Increased Safety | Ex e II C Gb EN 60079-7 2007 |
| Ex ta Dust Ignition Proof | Ex ta IIIC DA IP6X IEC 60079-31 2008 |
| Sira Certificate no: IECEx SIR 10.0094X | |
| Ex d Flameproof | Ex d I Mb IEC 60079-1 2007 |
| Ex d Flameproof | Ex d II C Gb IEC 60079-1 2007 |
| Ex e Increased Safety | Ex e I Mb IEC 60079-7 2006-7 |
| Ex e Increased Safety | Ex e II C Gb IEC 60079-7 2006-7 |
| Ex ta Dust Ignition Proof | Ex ta IIIC DA IP6X IEC 60079-31 2008 |
| GOST APPROVAL no. | POCC GB.HO06.B00207 |
Are you interested in this product? Do you need additional information or individual pricing?
Typical Applications:
Certificates:



Features:
Flameproof protection made of high-quality brass with an IP rating of: IP66 + IP67 + IP68(5bar) + IP69K. For indoor and outdoor use, Zone 1, Zone 2, Zone 21, and Zone 22 hazardous areas, protecting all types of cables in sealed LTP conduits. Brass gland with nylon seal and two-part epoxy resin.
| Size | Name | Thread size | Dimensions [mm] | ||||
|---|---|---|---|---|---|---|---|
| A | B | C | D (A/F) | E (A/F) | F (I/D) | ||
| 16 |
LTP16-M20-EXD |
M20x1.5 | 15 | 32 | 29 | 30 | 10.7 |
LTP20-M20-EXD |
M20x1.5 | 15 | 32 | 29 | 30 | 13.0 | |
| 25 |
LTP25-M25-EXD |
M25x1.5 | 15 | 35 | 35 | 36 | 18.0 |
| 32 |
LTP32-M32-EXD |
M32x1.5 | 15 | 37 | 42 | 46 | 24.0 |
| 40 |
LTP40-M40-EXD |
M40x1.5 | 15 | 38 | 52 | 52 | 30.4 |
| 50 |
LTP50-M50-EXD |
M50x1.5 | 15 | 40 | 58 | 60 | 37.0 |
| 63 |
LTP63-M63-EXD |
M63x1.5 | 15 | 40 | 70 | 70 | |
Features:
Flameproof protection made of high-quality brass with an IP rating of: IP66 + IP67 + IP68(5bar) + IP69K. Suitable for indoor and outdoor use, Zone 1, Zone 2, Zone 21, and Zone 22 hazardous areas, protecting all types of cables in sealed LTP conduits. Brass gland with nylon seal and two-part epoxy resin.
| Size | Name | NTP thread size | Dimensions [mm] | ||||
|---|---|---|---|---|---|---|---|
| A | B | C | D (A/F) | E (A/F) | F (I/D) | ||
| 16 |
LTP16-050-EXD |
½” | 20 | 32 | 29 | 30 | 10.7 |
LTP20-050-EXD |
½” | 20 | 32 | 29 | 30 | 13.0 | |
| 25 |
LTP25-075-EXD |
¾” | 20 | 35 | 35 | 36 | 18.0 |
| 32 |
LTP32-100-EXD |
1" | 25 | 37 | 42 | 46 | 24.0 |
| 40 |
LTP40-125-EXD |
1 ¼” | 26 | 52 | 52 | 30.4 | |
| 50 |
LTP50-150-EXD |
1 ½” | 26 | 40 | 58 | 60 | 37.0 |
| 63 |
LTP63-200-EXD |
2” | 15 | 40 | 70 | 70 | 48.4 |
Features:
Flameproof protection made of high-quality stainless steel (316) with an IP rating of IP66 + IP67 + IP68(5bar) + IP69K. For indoor and outdoor use, Zone 1, Zone 2, Zone 21, and Zone 22 hazardous areas, protecting all types of cables in sealed LTP conduits. Stainless steel (316) cable gland with a nylon seal and two-part epoxy resin. NTP thread version available upon request.
| Size | Name | Thread size | Dimensions [mm] | ||||
|---|---|---|---|---|---|---|---|
| A | B | C | D (A/F) | E (A/F) | F (I/D) | ||
| 20 |
LTP20-M20-EXD-SS |
M20x1.5 | 15 | 32 | 29 | 30 | 13.0 |
| 25 |
LTP25-M25-EXD-SS |
15 | 35 | 35 | 36 | 18.0 | |
| 32 |
LTP32-M32-EXD-SS |
M32x1.5 | 15 | 37 | 42 | 46 | 24.0 |
| 40 |
LTP40-M40-EXD-SS |
M40x1.5 | 15 | 38 | 52 | 30.4 | |
| 50 |
LTP50-M50-EXD-SS |
M50x1.5 | 15 | 40 | 58 | 60 | 37.0 |
| 63 |
LTP63-M63-EXD-SS |
M63x1.5 | 15 | 40 | 70 | 70 | 48.4 |
| ATEX APPROVAL to EN60079-0 2009 | |
| Ex d Flameproof | Ex d I Mb EN 60079-1 2007 |
| Ex d Flameproof | Ex d II C Gb EN 60079-1 2007 |
| Ex e Increased Safety | Ex e I Mb EN 60079-7 2007 |
| Ex e Increased Safety | Ex e II C Gb EN 60079-7 2007 |
| Ex ta Dust Ignition Proof | Ex ta IIIC DA IP6X IEC 60079-31 2008 |
| Sira Certificate no: IECEx SIR 10.0094X | |
| Ex d Flameproof | Ex d I Mb IEC 60079-1 2007 |
| Ex d Flameproof | Ex d II C Gb IEC 60079-1 2007 |
| Ex e Increased Safety | Ex e I Mb IEC 60079-7 2006-7 |
| Ex e Increased Safety | Ex e II C Gb IEC 60079-7 2006-7 |
| Ex ta Dust Ignition Proof | Ex ta IIIC DA IP6X IEC 60079-31 2008 |
| GOST APPROVAL no. | POCC GB.HO06.B00207 |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent