Recessing stops for IT devices for-12-IS

DLA-12-IS Surge Arrester for IT Devices

• Only 18 mm wide
• Replaceable plug-in module
• Ideal for symmetrical connections such as RS485 or 232 with one pair of wires
• Choice of indirect or direct shielding
• Galvanically separated grounding via a gas discharge tube
• 2-stage protection
• Complies with the IEC 61643-21 standard
• Recommended for photovoltaic power plants with RS485
and wide-area systems

Technical data

Description FOR-12-IS
Application RS485, RS232
Rated voltage Un 12V
Max. perm. DC/AC operating voltage Uc 15V / 10V
Max. operating current** IL 2.4A
C3 Voltage protection level at In Up 30V** / <640V
C2 Rated discharge current
In: 10 x 8/20µs
In 5kA
Limit leakage current
Imax: 1 x 8/20µs
Imax 20kA
D1 Surge current
Iimp: 2 x 10/350µs
Iimp 5kA
Impedance per line R 0 Ω
Capacity C <25pF
Activation time <10 ns
Device damaged short circuit

Mechanical Properties
Configuration DLA-IS = 1 double wire + shield + Signal-Ground
Mounting Method TH35 mm mounting rail
Housing dimensions See drawing
Cable cross-section Min/max 0.4/1.5 mm²
Housing material UL94-V0 thermoplastic
Grounding via TH35 rail and screw terminal
Replacement module DLAM-12-IS
Control Standards
IEC 61643-21 International SPD for telecommunications and signaling networks

Article number 640152
Replacement module 64015200

Dimensions and diagram

Surge arresters for IT devices DLA-12-IS dimensions

Surge arresters for IT devices DLA-12-IS schematic

P: 3-pole gas discharge tube
Pb: 2-pole gas discharge tube
R: Resistance or coil
D: Diode

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

DLA-12-IS Surge Arrester for IT Devices

• Only 18 mm wide
• Replaceable plug-in module
• Ideal for symmetrical connections such as RS485 or 232 with one pair of wires
• Choice of indirect or direct shielding
• Galvanically separated grounding via a gas discharge tube
• 2-stage protection
• Complies with the IEC 61643-21 standard
• Recommended for photovoltaic power plants with RS485
and wide-area systems

Technical data

Description FOR-12-IS
Application RS485, RS232
Rated voltage Un 12V
Max. perm. DC/AC operating voltage Uc 15V / 10V
Max. operating current** IL 2.4A
C3 Voltage protection level at In Up 30V** / <640V
C2 Rated discharge current
In: 10 x 8/20µs
In 5kA
Limit leakage current
Imax: 1 x 8/20µs
Imax 20kA
D1 Surge current
Iimp: 2 x 10/350µs
Iimp 5kA
Impedance per line R 0 Ω
Capacity C <25pF
Activation time <10 ns
Device damaged short circuit

Mechanical Properties
Configuration DLA-IS = 1 double wire + shield + Signal-Ground
Mounting Method TH35 mm mounting rail
Housing dimensions See drawing
Cable cross-section Min/max 0.4/1.5 mm²
Housing material UL94-V0 thermoplastic
Grounding via TH35 rail and screw terminal
Replacement module DLAM-12-IS
Control Standards
IEC 61643-21 International SPD for telecommunications and signaling networks

Article number 640152
Replacement module 64015200

Dimensions and diagram

Surge arresters for IT devices DLA-12-IS dimensions

Surge arresters for IT devices DLA-12-IS schematic

P: 3-pole gas discharge tube
Pb: 2-pole gas discharge tube
R: Resistance or coil
D: Diode