Category
Photos are for informational purposes only. View product specification
please use latin characters
Battery systems
|
Energy
|
Medical systems![]() |
Industrial
|
AbuseA situation of abuse (electrical, thermal, or physical) leads to internal short circuits, which causes internal heating. |
Electrolyte pressureThe electrolyte solution between the anode and cathode evaporates under the influence of increasing heat. The pressure inside the cell begins to rise. |
SENSOR ACTIVATION
|
Increase TemperatureInternal reactions cause the cell temperature to exceed a critical point, beyond which the cell temperature increases uncontrollably. |
Fire and ExplosionThe temperature increase causes uncontrolled combustion of the battery cell and the possibility of an explosion. |
| Parameter | BES Lite |
|---|---|
| Detection principle | Electrochemical detection |
| Dimensions [mm] W × L × H | 31.8 × 23.5 × 9.9 |
| Start-up time | 1 second to obtain a valid signal |
| Response time | < 2 seconds |
| Output Type | Analog Tri-State Output |
| Supply Voltage | 4.5 – 5.5 V DC |
| Operating Temperature | -20°C to 70°C |
| Humidity | 10% to 90% RH (non-condensing) |
| Lifespan | ≥ 10 years |
| Degree protection | IP30 |
| Weight | 4.5 g |

Are you interested in this product? Do you need additional information or individual pricing?
Battery systems
|
Energy
|
Medical systems![]() |
Industrial
|
AbuseA situation of abuse (electrical, thermal, or physical) leads to internal short circuits, which causes internal heating. |
Electrolyte pressureThe electrolyte solution between the anode and cathode evaporates under the influence of increasing heat. The pressure inside the cell begins to rise. |
SENSOR ACTIVATION
|
Increase TemperatureInternal reactions cause the cell temperature to exceed a critical point, beyond which the cell temperature increases uncontrollably. |
Fire and ExplosionThe temperature increase causes uncontrolled combustion of the battery cell and the possibility of an explosion. |
| Parameter | BES Lite |
|---|---|
| Detection principle | Electrochemical detection |
| Dimensions [mm] W × L × H | 31.8 × 23.5 × 9.9 |
| Start-up time | 1 second to obtain a valid signal |
| Response time | < 2 seconds |
| Output Type | Analog Tri-State Output |
| Supply Voltage | 4.5 – 5.5 V DC |
| Operating Temperature | -20°C to 70°C |
| Humidity | 10% to 90% RH (non-condensing) |
| Lifespan | ≥ 10 years |
| Degree protection | IP30 |
| Weight | 4.5 g |