CYLINDRICAL CAPACITORS FOR POWER FACTOR CORRECTION

Electrical data:
Voltage range:
230V/50Hz - 910V/50Hz
Power:
2,3kVAr - 250 kVAr
   
It is possible to purchase the whole battery with regulator. For details please contact DACPOL

 
CYLINDRICAL CAPACITORS

 

Electrical data
Standards:
IEC 831-1+2/88, EN 60831-1+2/93, VDE 560-46+47 3/95
Over voltage
Ucn + 10% (up to 8 hours per day)
 
Ucn + 15% (up to 30 minutes per day)
 
Ucn + 20% (up to 5 minutes)
 
Ucn + 30% (do1 minutes)
Over current:
1,3 * In,
 
1,3 * with 10% over voltage,
 
with 15% over capacity and THD
capacity tolerance
-5/ + 10%
Voltage test
(terminal - terminal)       2,15 * Ucn, AC, 2 sec
 
((terminal - casing)        4800 VAC, 2 sec
Test current
200*In
Losses
0,25 W/kVAr
Life time:
> 100 000 hours
IP
IP00
Operation temperature
-25 / D (55°C), (-40 / D for request)
Casing temperature
 65°C
Cooling
Natural air
Humidity
max. 95%
Maximum operation height:
2000 m above sea level
Assembly : vertical
 
Assembly:
M12 screw
Protection
Over pressure safety device, self regenerating
Casing:
Aluminium box
Dielectric
polypropylene foil , metallized with zinc
Impregnate:
Natural oil
Electrical terminals
casing Ø 84 mm: M5 screw in
 
Casing  Ø

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

CYLINDRICAL CAPACITORS FOR POWER FACTOR CORRECTION

Electrical data:
Voltage range:
230V/50Hz - 910V/50Hz
Power:
2,3kVAr - 250 kVAr
   
It is possible to purchase the whole battery with regulator. For details please contact DACPOL

 
CYLINDRICAL CAPACITORS

 

Electrical data
Standards:
IEC 831-1+2/88, EN 60831-1+2/93, VDE 560-46+47 3/95
Over voltage
Ucn + 10% (up to 8 hours per day)
 
Ucn + 15% (up to 30 minutes per day)
 
Ucn + 20% (up to 5 minutes)
 
Ucn + 30% (do1 minutes)
Over current:
1,3 * In,
 
1,3 * with 10% over voltage,
 
with 15% over capacity and THD
capacity tolerance
-5/ + 10%
Voltage test
(terminal - terminal)       2,15 * Ucn, AC, 2 sec
 
((terminal - casing)        4800 VAC, 2 sec
Test current
200*In
Losses
0,25 W/kVAr
Life time:
> 100 000 hours
IP
IP00
Operation temperature
-25 / D (55°C), (-40 / D for request)
Casing temperature
 65°C
Cooling
Natural air
Humidity
max. 95%
Maximum operation height:
2000 m above sea level
Assembly : vertical
 
Assembly:
M12 screw
Protection
Over pressure safety device, self regenerating
Casing:
Aluminium box
Dielectric
polypropylene foil , metallized with zinc
Impregnate:
Natural oil
Electrical terminals
casing Ø 84 mm: M5 screw in
 
Casing  Ø