Category
Photos are for informational purposes only. View product specification
please use latin characters
The Exepd type AB1-S3 buzzer is used to provide alarm signaling – via a piercing, acoustic signal – to safely warn of possible hazards in explosion-hazardous areas.
A high IP protection rating and a corrosion-resistant stainless steel housing ensure a long service life of the device, even in aggressive environmental conditions. The buzzer can be used in a variety of applications in explosion-hazardous areas. Thanks to its approval as a device, it can be mounted directly on the front of a machine – without the need for additional certification.
It has also been tested for installation in certified control panels with Ex e, Ex t, and Ex d protection.
Note: The lock nut is not included in the scope of delivery.
Category | Parameter | Value |
---|---|---|
Explosion-proof | Protection type | II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T80 °C Db |
Certificate | TÜV A 20 ATEX 0102X | |
Ambient temperature | -40 °C ... +60 °C | |
Electrical data | Supply voltage | 24 VDC |
Power consumption | max. 30 mA | |
Fuse | 63 mA | |
Frequency | 4300 Hz | |
Volume | 85 dB / 40 cm | |
Electrical connection | 2 x 0.5 mm², Ø 4.8 mm | |
Wire colors | brown = +24 VDC blue = 0 V |
|
Casing | Stainless steel 1.4305 | |
Padding | EPDM | |
Protection level | IP66 / IP30 head | |
Mounting hole | 22.0 ... 22.3 mm / M22 x 1.5 | |
Tightening torque | 8 Nm | |
Max. wall thickness | 10.0 ... 15.0 mm | |
Logistics data | Weight | 150 g (1.5 m cable) |
Customs code | 8531 8000 – Germany |
Are you interested in this product? Do you need additional information or individual pricing?
The Exepd type AB1-S3 buzzer is used to provide alarm signaling – via a piercing, acoustic signal – to safely warn of possible hazards in explosion-hazardous areas.
A high IP protection rating and a corrosion-resistant stainless steel housing ensure a long service life of the device, even in aggressive environmental conditions. The buzzer can be used in a variety of applications in explosion-hazardous areas. Thanks to its approval as a device, it can be mounted directly on the front of a machine – without the need for additional certification.
It has also been tested for installation in certified control panels with Ex e, Ex t, and Ex d protection.
Note: The lock nut is not included in the scope of delivery.
Category | Parameter | Value |
---|---|---|
Explosion-proof | Protection type | II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T80 °C Db |
Certificate | TÜV A 20 ATEX 0102X | |
Ambient temperature | -40 °C ... +60 °C | |
Electrical data | Supply voltage | 24 VDC |
Power consumption | max. 30 mA | |
Fuse | 63 mA | |
Frequency | 4300 Hz | |
Volume | 85 dB / 40 cm | |
Electrical connection | 2 x 0.5 mm², Ø 4.8 mm | |
Wire colors | brown = +24 VDC blue = 0 V |
|
Casing | Stainless steel 1.4305 | |
Padding | EPDM | |
Protection level | IP66 / IP30 head | |
Mounting hole | 22.0 ... 22.3 mm / M22 x 1.5 | |
Tightening torque | 8 Nm | |
Max. wall thickness | 10.0 ... 15.0 mm | |
Logistics data | Weight | 150 g (1.5 m cable) |
Customs code | 8531 8000 – Germany |