Category
Photos are for informational purposes only. View product specification
please use latin characters
The S6XM and S9XM single-phase pass-through power meters can measure currents up to 300 A AC/DC, operating similarly to a current transformer, and voltages up to 1000 V.
Thanks to the built-in Modbus RTU interface, measurement data can be transmitted at 115,200 baud via the RS485 port.
They are ideal for measurements in renewable energy systems, Smart Grids, and LED lighting due to their ability to measure harmonic distortion (THD).
In 3-phase systems, they also enable measurements in the Aron configuration.
|
|
S6XM50A1000VM | S6XM50A100VM | S9XM300A1000VM | S9XM300A100VM |
|---|---|---|---|---|
| Interface |
Modbus RTU |
Modbus RTU |
Modbus RTU |
Modbus RTU |
| AC Current |
50A |
50A |
300A |
300A |
| DC Current |
50A |
50A |
400A |
400A |
| AC voltage |
800V |
80V |
800V |
80V |
| DC voltage |
1000V |
100V |
1000V |
100V |
| Dimensions |
46.1 x 63 x 26.4 |
46.1 x 63 x 26.4 |
89.1 x 99.25 x 28.5 |
89.1 x 99.25 x 28.5 |
| Hole diameter |
15 mm |
15 mm |
33 mm |
33 mm |
| Weight |
80 g |
80 g |
370 g |
370 g |
| Power |
9...30 V DC |
|---|---|
| Power Consumption |
< 1.3 W |
| Accuracy |
|
| Temperature coefficient |
< 200 ppm/°C |
| Operating temperature |
-15 to +65°C |
| Storage temperature |
-40 to +85°C |
| Humidity |
10 to 90% (non-condensing) |
| Height |
Up to 2000 m above sea level |
| Standards |
EN61000-6-4/2006, EN64000-6-2/2005, EN61010-1/2010 |
| Certificates | CE |
| Configuration |
Via free software or Modbus RTU (RS485). |
RMS current, DC current, RMS voltage, DC voltage, active/reactive/apparent power, Cosϕ, bidirectional active energy, THD. Peak and minimum values of measurement values.
Are you interested in this product? Do you need additional information or individual pricing?
The S6XM and S9XM single-phase pass-through power meters can measure currents up to 300 A AC/DC, operating similarly to a current transformer, and voltages up to 1000 V.
Thanks to the built-in Modbus RTU interface, measurement data can be transmitted at 115,200 baud via the RS485 port.
They are ideal for measurements in renewable energy systems, Smart Grids, and LED lighting due to their ability to measure harmonic distortion (THD).
In 3-phase systems, they also enable measurements in the Aron configuration.
|
|
S6XM50A1000VM | S6XM50A100VM | S9XM300A1000VM | S9XM300A100VM |
|---|---|---|---|---|
| Interface |
Modbus RTU |
Modbus RTU |
Modbus RTU |
Modbus RTU |
| AC Current |
50A |
50A |
300A |
300A |
| DC Current |
50A |
50A |
400A |
400A |
| AC voltage |
800V |
80V |
800V |
80V |
| DC voltage |
1000V |
100V |
1000V |
100V |
| Dimensions |
46.1 x 63 x 26.4 |
46.1 x 63 x 26.4 |
89.1 x 99.25 x 28.5 |
89.1 x 99.25 x 28.5 |
| Hole diameter |
15 mm |
15 mm |
33 mm |
33 mm |
| Weight |
80 g |
80 g |
370 g |
370 g |
| Power |
9...30 V DC |
|---|---|
| Power Consumption |
< 1.3 W |
| Accuracy |
|
| Temperature coefficient |
< 200 ppm/°C |
| Operating temperature |
-15 to +65°C |
| Storage temperature |
-40 to +85°C |
| Humidity |
10 to 90% (non-condensing) |
| Height |
Up to 2000 m above sea level |
| Standards |
EN61000-6-4/2006, EN64000-6-2/2005, EN61010-1/2010 |
| Certificates | CE |
| Configuration |
Via free software or Modbus RTU (RS485). |
RMS current, DC current, RMS voltage, DC voltage, active/reactive/apparent power, Cosϕ, bidirectional active energy, THD. Peak and minimum values of measurement values.
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent