1-phase power transducers
1-phase power transducers
1-phase power transducers
1-phase power transducers
1-phase power transducers

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: TELE Haase

1-phase power transducers

The S6XM and S9XM single-phase pass-through power meters can measure currents up to 300 A AC/DC, operating similarly to a current transformer, and voltages up to 1000 V.

Thanks to the built-in Modbus RTU interface, measurement data can be transmitted at 115,200 baud via the RS485 port.

They are ideal for measurements in renewable energy systems, Smart Grids, and LED lighting due to their ability to measure harmonic distortion (THD).

In 3-phase systems, they also enable measurements in the Aron configuration.

S6XM50A1000VM S6XM50A100VM S9XM300A1000VM S9XM300A100VM
Interface

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

AC Current

50A

50A

300A

300A

DC Current

50A

50A

400A

400A

AC voltage

800V

80V

800V

80V

DC voltage

1000V

100V

1000V

100V

Dimensions

46.1 x 63 x 26.4

46.1 x 63 x 26.4

89.1 x 99.25 x 28.5

89.1 x 99.25 x 28.5

Hole diameter

15 mm

15 mm

33 mm

33 mm

Weight

80 g

80 g

370 g

370 g

Other technical data of thesingle-phase continuous power meter:

Power

9...30 V DC

Power Consumption

< 1.3 W

Accuracy
  • Voltage, Current, Active Power: < 0.5% f.s.
  • Frequency: +/- 0.1 Hz
  • Energy: +/- 1% of indication
  • V peak, I peak: +/- 5% f.s.
Temperature coefficient

< 200 ppm/°C

Operating temperature

-15 to +65°C

Storage temperature

-40 to +85°C

Humidity

10 to 90% (non-condensing)

Height

Up to 2000 m above sea level

Standards

EN61000-6-4/2006, EN64000-6-2/2005, EN61010-1/2010

Certificates CE
Configuration

Via free software or Modbus RTU (RS485).

Single-phase power meter measurement values:

RMS current, DC current, RMS voltage, DC voltage, active/reactive/apparent power, Cosϕ, bidirectional active energy, THD. Peak and minimum values ​​of measurement values.

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

The S6XM and S9XM single-phase pass-through power meters can measure currents up to 300 A AC/DC, operating similarly to a current transformer, and voltages up to 1000 V.

Thanks to the built-in Modbus RTU interface, measurement data can be transmitted at 115,200 baud via the RS485 port.

They are ideal for measurements in renewable energy systems, Smart Grids, and LED lighting due to their ability to measure harmonic distortion (THD).

In 3-phase systems, they also enable measurements in the Aron configuration.

S6XM50A1000VM S6XM50A100VM S9XM300A1000VM S9XM300A100VM
Interface

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

AC Current

50A

50A

300A

300A

DC Current

50A

50A

400A

400A

AC voltage

800V

80V

800V

80V

DC voltage

1000V

100V

1000V

100V

Dimensions

46.1 x 63 x 26.4

46.1 x 63 x 26.4

89.1 x 99.25 x 28.5

89.1 x 99.25 x 28.5

Hole diameter

15 mm

15 mm

33 mm

33 mm

Weight

80 g

80 g

370 g

370 g

Other technical data of thesingle-phase continuous power meter:

Power

9...30 V DC

Power Consumption

< 1.3 W

Accuracy
  • Voltage, Current, Active Power: < 0.5% f.s.
  • Frequency: +/- 0.1 Hz
  • Energy: +/- 1% of indication
  • V peak, I peak: +/- 5% f.s.
Temperature coefficient

< 200 ppm/°C

Operating temperature

-15 to +65°C

Storage temperature

-40 to +85°C

Humidity

10 to 90% (non-condensing)

Height

Up to 2000 m above sea level

Standards

EN61000-6-4/2006, EN64000-6-2/2005, EN61010-1/2010

Certificates CE
Configuration

Via free software or Modbus RTU (RS485).

Single-phase power meter measurement values:

RMS current, DC current, RMS voltage, DC voltage, active/reactive/apparent power, Cosϕ, bidirectional active energy, THD. Peak and minimum values ​​of measurement values.

Comments (0)