CASR 6-NP current transducer
CASR 6-NP current transducer

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: LEM

CASR 6-NP current transducer

  • CASR 6-NP
  • Accuracy 0.8
  • Rated Current [A] 6
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] 5
  • Mounting [THT / SMD / DIN / Panel / On primary rail] THT
  • App Automotive Drive/Power Supplies/Renewable Energy/Welding Machines
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -40
  • Maximum operating temperature [°C] 85
  • Frequency response (-3dB) [kHz] 300
  • Feedback loop [open / closed] // Eta technology closed

Technical Specifications

Description

Designed for electronic current measurement: DC, AC, pulsed, etc., with galvanic isolation between primary and secondary circuits.

Main Features
  • Very low offset temperature coefficient
  • Very good dv/dt immunity
  • LTSR compatible
  • Reduced height
  • Multi-range closed-loop current transducer (with compensation)
  • Single power supply
  • Voltage output
  • Insulating plastic housing material compliant with UL 94-V0
  • Compact design for PCB mounting
  • Reference pin with two modes: Ref IN and Ref OUT
Applications
  • Variable Speed ​​AC Drives and Servo Motors
  • Static Converters for DC Drives
  • Battery-Powered Applications
  • UPS (Uninterruptible Power Supplies)
  • Switched-Mode Power Supplies
  • Power Supplies for Welding Applications
  • Solar Inverters
Technical Data
Parameter Value
Maximum Voltage Power Supply 7V
Maximum Primary Conductor Temperature 110°C
Maximum Ambient Air Temperature 105°C
Maximum Steady State Primary Current 20xIpn
Maximum Discharge Voltage (HBM) 4kV
Secondary Supply Voltage 5V DC
Voltage Output 0÷5V
Primary rated current 6A
Primary current measurement range -20÷20A
Supply voltage 5V
Reference voltage (for primary current Ip=0) 2.5V
External reference voltage 0÷4V
Output voltage (for primary current Ip=0) Reference voltage Vref
Electrical offset voltage -5.3÷5.3mV
Electrical offset current relative to primary current -51÷51mA
Theoretical sensitivity 104.2 mV/A
Sensitivity error -0.7÷0.7%
60.27 PLN
60.27 PLN Gross price / pcs.
49.00 PLN Net price / pc.
Tax included

Availability: Please be advised that this product is out of stock

You can place a pre-order, report your interest in the product by clicking the "Ask for availability" button.

Out of stock
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

  • Accuracy 0.8
  • Rated Current [A] 6
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] 5
  • Mounting [THT / SMD / DIN / Panel / On primary rail] THT
  • App Automotive Drive/Power Supplies/Renewable Energy/Welding Machines
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -40
  • Maximum operating temperature [°C] 85
  • Frequency response (-3dB) [kHz] 300
  • Feedback loop [open / closed] // Eta technology closed

Technical Specifications

Description

Designed for electronic current measurement: DC, AC, pulsed, etc., with galvanic isolation between primary and secondary circuits.

Main Features
  • Very low offset temperature coefficient
  • Very good dv/dt immunity
  • LTSR compatible
  • Reduced height
  • Multi-range closed-loop current transducer (with compensation)
  • Single power supply
  • Voltage output
  • Insulating plastic housing material compliant with UL 94-V0
  • Compact design for PCB mounting
  • Reference pin with two modes: Ref IN and Ref OUT
Applications
  • Variable Speed ​​AC Drives and Servo Motors
  • Static Converters for DC Drives
  • Battery-Powered Applications
  • UPS (Uninterruptible Power Supplies)
  • Switched-Mode Power Supplies
  • Power Supplies for Welding Applications
  • Solar Inverters
Technical Data
Parameter Value
Maximum Voltage Power Supply 7V
Maximum Primary Conductor Temperature 110°C
Maximum Ambient Air Temperature 105°C
Maximum Steady State Primary Current 20xIpn
Maximum Discharge Voltage (HBM) 4kV
Secondary Supply Voltage 5V DC
Voltage Output 0÷5V
Primary rated current 6A
Primary current measurement range -20÷20A
Supply voltage 5V
Reference voltage (for primary current Ip=0) 2.5V
External reference voltage 0÷4V
Output voltage (for primary current Ip=0) Reference voltage Vref
Electrical offset voltage -5.3÷5.3mV
Electrical offset current relative to primary current -51÷51mA
Theoretical sensitivity 104.2 mV/A
Sensitivity error -0.7÷0.7%
Comments (0)