Metallic conduit
  • Metallic conduit

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: FLEXICON

Metal flesh - statement

FU

FSU

LFHU

LTPE

LTP

Construction:
Galvanised steel,
helically wound, flexible conduit.
Colour zinc, self colour.
Construction:
Galvanised steel,
helically wound, flexible conduit with pvc coating. Colour black.
Grey or orange on request.*
Construction:
Galvanised steel,
helically wound, flexible steel
conduit with Low Fire Hazard
(LFH) coating.
Colour black.
Construction:
Galvanised steel, helically
wound, flexible conduit with smooth pvc
cover. Colour black
Construction:
Galvanised steel,
helically wound, flexible conduit with
smooth oil resistant and high
temperature pvc cover. Colour black.
Grey or orange on request.*
Typical Applications:
Underfloor wiring in office blocks
Typical Applications:
General factory wiring and connections to machines
Typical Applications:
Public and commercial buildings and tunnels..
Typical Applications:
Machine tools or outdoor installations where liquid tight is a requirement.
Typical Applications:
Machine tools or outdoor installations where liquid tight
is a requirement.

 

 

 

 

 

High mechanical strength
Highly flexible
Inherently Low Fire Hazard (LFH)
Fully compliant to LUL Std I-085
Temperature range:
-100˚C to +300˚C
IP rating: IP40
Nickel plated brass fittings

High mechanical strength
Highly flexible
IP rating:
-IP54 with standard fittings,
-IP65 with type C
compression fittings
Temperature range:
- -15˚C to +70˚C
Low Fire Hazard version available
(LFHU)
Nickel plated brass fittings

High mechanical strength
Highly flexible
IP rating:
- IP54 with standard fittings,
- IP65 with type C
compression fittings
Extra low Fire Hazard UL94 V0,
Halogen, sulphur and
phosphorus free
Compliant to LUL Std 1-085
Temperature range: -25˚C to +90˚C
Nickel plated brass fittings
Vibration and shock tested to EN61373 Cat 2
High mechanical strength
IP rating: IP66 + IP67 + IP68 (5 bar)
+ IP69K
Smooth, wipe clean outer cover
Cover does not wrinkle when bent
Temperature range:
-15˚C to +70˚C
Good flexibility
UV resistant (black) and suitable for external use
Nickel plated brass or stainless steel fittings
Vibration and shock tested to EN61373 Cat 2
High mechanical strength
IP rating: IP66 + IP67 + IP68 (5 bar) + IP69K
Smooth, wipe clean outer cover
Cover does not wrinkle when bent
Temperature range:
-20˚C to +105˚C
Lloyd’s Register Type Approval
Good flexibility
UV resistant (black) and suitable for external use
Nickel plated brass or stainless steel fittings
Vibration and shock tested to EN61373 Cat 2

Metallic conduit)

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

FU

FSU

LFHU

LTPE

LTP

Construction:
Galvanised steel,
helically wound, flexible conduit.
Colour zinc, self colour.
Construction:
Galvanised steel,
helically wound, flexible conduit with pvc coating. Colour black.
Grey or orange on request.*
Construction:
Galvanised steel,
helically wound, flexible steel
conduit with Low Fire Hazard
(LFH) coating.
Colour black.
Construction:
Galvanised steel, helically
wound, flexible conduit with smooth pvc
cover. Colour black
Construction:
Galvanised steel,
helically wound, flexible conduit with
smooth oil resistant and high
temperature pvc cover. Colour black.
Grey or orange on request.*
Typical Applications:
Underfloor wiring in office blocks
Typical Applications:
General factory wiring and connections to machines
Typical Applications:
Public and commercial buildings and tunnels..
Typical Applications:
Machine tools or outdoor installations where liquid tight is a requirement.
Typical Applications:
Machine tools or outdoor installations where liquid tight
is a requirement.

 

 

 

 

 

High mechanical strength
Highly flexible
Inherently Low Fire Hazard (LFH)
Fully compliant to LUL Std I-085
Temperature range:
-100˚C to +300˚C
IP rating: IP40
Nickel plated brass fittings

High mechanical strength
Highly flexible
IP rating:
-IP54 with standard fittings,
-IP65 with type C
compression fittings
Temperature range:
- -15˚C to +70˚C
Low Fire Hazard version available
(LFHU)
Nickel plated brass fittings

High mechanical strength
Highly flexible
IP rating:
- IP54 with standard fittings,
- IP65 with type C
compression fittings
Extra low Fire Hazard UL94 V0,
Halogen, sulphur and
phosphorus free
Compliant to LUL Std 1-085
Temperature range: -25˚C to +90˚C
Nickel plated brass fittings
Vibration and shock tested to EN61373 Cat 2
High mechanical strength
IP rating: IP66 + IP67 + IP68 (5 bar)
+ IP69K
Smooth, wipe clean outer cover
Cover does not wrinkle when bent
Temperature range:
-15˚C to +70˚C
Good flexibility
UV resistant (black) and suitable for external use
Nickel plated brass or stainless steel fittings
Vibration and shock tested to EN61373 Cat 2
High mechanical strength
IP rating: IP66 + IP67 + IP68 (5 bar) + IP69K
Smooth, wipe clean outer cover
Cover does not wrinkle when bent
Temperature range:
-20˚C to +105˚C
Lloyd’s Register Type Approval
Good flexibility
UV resistant (black) and suitable for external use
Nickel plated brass or stainless steel fittings
Vibration and shock tested to EN61373 Cat 2

Metallic conduit)