Menu
-
BackX
-
Components
-
-
Category
-
Semiconductors
- Diodes
- Thyristors
-
Electro-insulated Modules
- Electro-insulated Modules | VISHAY (IR)
- Electro-insulated Modules | INFINEON (EUPEC)
- Electro-insulated Modules | Semikron
- Electro-insulated Modules | POWEREX
- Electro-insulated Modules | IXYS
- Electro-insulated Modules | POSEICO
- Electro-insulated Modules | ABB
- Electro-insulated Modules | TECHSEM
- Go to the subcategory
- Bridge Rectifiers
-
Transistors
- Transistors | GeneSiC
- SiC MOSFET Modules | Mitsubishi
- SiC MOSFET Modules | STARPOWER
- Module SiC MOSFET ABB’s
- IGBT Modules | MITSUBISHI
- Transistor Modules | MITSUBISHI
- MOSFET Modules | MITSUBISHI
- Transistor Modules | ABB
- IGBT Modules | POWEREX
- IGBT Modules | INFINEON (EUPEC)
- Silicon Carbide (SiC) semiconductor elements
- Go to the subcategory
- Gate Drivers
- Power Blocks
- Go to the subcategory
-
Electrical Transducers
-
Current Transducers | LEM
- Closed-Loop Current Transducers (C/L)
- Open-Loop Current Transducers (O/L)
- Current Transducers supplied with unipolar voltage
- 'Eta' Current Transducers
- Current Transducers - LF xx10 Series
- Current Transducers - LH Series
- Current Transducer - HOYL and HOYS Series
- Current Transducers - GO–SME & GO–SMS Series
- AUTOMOTIVE current transducers
- Go to the subcategory
-
Voltage Transducers | LEM
- Voltage Transducers - LV Series
- Voltage Transducers - DVL Series
- Precision Voltage Transducers with double magnetic core - CV Series
- Voltage Transducer for Traction - DV 4200/SP4
- Voltage Transducers - DVM Series
- Voltage Transducer - DVC 1000-P
- Voltage Transducers - DVC 1000 Series
- Go to the subcategory
- Transducers for Protection, Monitoring and Control | LEM
- Split-core Transducers | LEM
- Precision Current Transducers | LEM
- Go to the subcategory
-
Current Transducers | LEM
-
Passive components (capacitors, resistors, fuses, filters)
- Resistors
-
Fuses
- Miniature Fuses for electronic circuits - ABC & AGC Series
- Tubular Fast-acting Fuses
- Time-delay Fuse Links with GL/GG & AM characteristics
- Ultrafast Fuse Links
- Fast-acting Fuses (British & American standard)
- Fast-acting Fuses (European standard)
- Traction Fuses
- High-voltage Fuse Links
- Go to the subcategory
- Capacitors
- EMI Filters
- Supercapacitors
- Power surge protection
- Go to the subcategory
-
Relays and Contactors
- Relays and Contactors - Theory
- 3-Phase AC Semiconductor Relays
- DC Semiconductor Relays
- Controllers, Control Systems and Accessories
- Soft Starters and Reversible Relays
- Electromechanical Relays
- Contactors
- Rotary Switches
-
Single-Phase AC Semiconductor Relays
- AC ONE PHASE RELAYS 1 series| D2425 | D2450
- One phase semiconductor AC relays CWA and CWD series
- One phase semiconductor AC relays CMRA and CMRD series
- One phase semiconductor AC relays - PS series
- Double and quadruple semiconductor AC relays - D24 D, TD24 Q, H12D48 D series
- One phase semiconductor relays - gn series
- Ckr series single phase solid state relays
- One phase AC semiconductor relays for DIN bus - ERDA I ERAA series
- 150A AC single phase relays
- Rail Mountable Solid State Relays With Integrated Heat Sink - ENDA, ERDA1 / ERAA1 series
- Go to the subcategory
- Single-Phase AC Semiconductor Relays for PCBs
- Interface Relays
- Go to the subcategory
- Cores and Other Inductive Components
- Heatsinks, Varistors, Thermal Protection
- Fans
- Air Conditioning, Accessories for Electrical Cabinets, Coolers
-
Batteries, Chargers, Buffer Power Supplies and Inverters
- Batteries, Chargers - Theoretical Description
- Modular Li-ion Battery Building Blocks, Custom Batteries, BMS
- Batteries
- Battery Chargers and Accessories
- Uninterruptible Power Supply and Buffer Power Supplies
- Inverters and Photovoltaic Equipments
- Energy storage
- Fuel cells
- Lithium-ion batteries
- Go to the subcategory
-
Automatics
- Limit Switches, Microswitches
- Sensors, Transducers
-
Infrared Thermometers (Pyrometers)
- IR-TE Series - Water-proof Palm-sized Radiation Thermometer
- IR-TA Series - Handheld Type Radiation Thermometer
- IR-H Series - Handheld Type Radiation Thermometer
- IR-BA Series - High-speed Compact Radiation Thermometer
- IR-FA Series - Fiber Optic Radiation Thermometer
- IR-BZ Series - Compact Infrared Thermometers
- Go to the subcategory
- Counters, Time Relays, Panel Meters
- Industrial Protection Devices
- Light and Sound Signalling
- Thermographic Camera
- LED Displays
- Control Equipments
-
Recorders
- Hybrid Recorders - AL3000 Series | CHINO
- Graphic Recorder - KR2000 Series | CHINO
- Ubiquitous Recorders - KR5000 Series | CHINO
- Palm-sized Temperature/Humidity Meters - HN-CH Series | CHINO
- Consumables for Recorders
- 71VR1 - Compact Paperless Recorder | M-SYSTEM
- Graphic Recorder - KR3000 Series | CHINO
- PC Recorders - R1M Series | M-SYSTEM
- PC Recorders - R2M Series | M-SYSTEM
- PC Recorders - RZMS Series | M-SYSTEM
- PC Recorders - RZUS Series | M-SYSTEM
- Go to the subcategory
- Drivers and Panels
- Go to the subcategory
-
Cables, Litz wires, Conduits, Flexible connections
- Wires
- Litz wires
- Cables for extreme applications
- Sleevings
-
Braids
- Flat Braids
- Round Braids
- Very Flexible Flat Braids
- Very Flexible Round Braids
- Cylindrical Cooper Braids
- Cylindrical Cooper Braids and Sleevings
- Flexible Earthing Connections
- Galvanized and Stainless Steel Cylindrical Braids
- PCV Insulated Copper Braids (temp. up to 85C)
- Flat Aluminium Braids
- Junction Set - Braids and Tubes
- Go to the subcategory
- Traction Equipment
- Cable Terminals
- Flexible Insulated Busbars
- Flexible Multilayer Busbars
- Cable Duct Systems
- Hoses
- Go to the subcategory
- View all categories
-
Semiconductors
-
-
- Suppliers
-
Applications
- CNC Machine Tools
- DC and AC Drives (Inverters)
- Energetics
- Equipment and Components for Hazardous Areas [Ex]
- Equipment for Distribution, Control and Telecommunications Cabinets
- HVAC Automation
- Induction Heating
- Industrial Automation
- Industrial Protective Devices
- Machines for Drying and Wood Processing
- Machines for Thermoforming Plastics
- Mining, Metallurgy and Foundry
- Motors and Transformers
- Power Supplies (UPS) and Rectifier Systems
- Printing
- Temperature Measurement and Regulation
- Test and Laboratory Measurements
- Tram and Railway Traction
- Welding Machines
-
Assembly
-
-
Montaż urządzeń
- Assembly of equipment on request
- Designing and Assembling of Busbar Cabinets, Switching Cabinets, Power Cabinets
- Power systems installation
- Power Electronics Equipment
- Machines built for order
- R&D research and development work
-
Industrial Testers
- Tester for diodes and thyristors measurement
- Thermal and motor circuit breakers testing stand
- Varistors and surge protectors testers
- Car fuses testing stand
- Tester for the power diode and thyristor reverse recovery charge Qrr measurement
- Rotor tester FD series
- Circuit breakers tester
- Tester for calibrating relays
- Video inspection tester for gas spring piston rods
- High-current thyristor switch
- Mesh ripping tester
- Go to the subcategory
- View all categories
-
-
-
Inductors
-
-
Modernizacja induktorów
- Repair of used inductors
- Modernization of inductors
-
Production of new inductors
- Inductors for crankshaft hardening
- Hardening of band saw teeth
- Inductors for heating elements before gluing
- Hardening of raceways of automotive wheel hub bearings
- Hardening of the drive transmission components
- Hardening of stepped shafts
- Heating in contraction joints
- Induction for scanning hardening
- Soft soldering
- Billet heaters
- Go to the subcategory
- Knowledge base
- View all categories
-
-
-
Induction devices
-
-
Urządzenia indukcyjne
-
Induction heating generators
-
Induction Heating Products Ambrell
- Generators power 500 W, frequency 150 - 400 kHz
- Generators power 1.2 - 2.4 kW, frequency 150 - 400 kHz
- Generators power 4.2 - 10 kW, frequency 150 - 400 kHz
- Generators power 10-15 kW, frequency 50-150 kHz
- Generators power 30-45 kW, frequency 50-150 kHz
- Generators power 65-135 kW, frequency 50-150 kHz
- Generators power 180-270 kW, frequency 50-150 kHz
- Generators power 20-35-50 kW, frequency 15-45 kHz
- Generators power 75-150 kW, frequency 15-45 kHz
- Generators power 200-500 kW, frequency 15-45 kHz
- Generators power 20-50 kW, frequency 5-15 kHz
- Go to the subcategory
- Induction heating products Denki Kogyo
-
JKZ induction heating generators
- Generators CX, frequency: 50-120kHz, power: 5-25kW
- Generators SWS, frequency: 15-30kHz, power: 25-260kW
- Molding and forging furnaces MFS, frequency: 0,5-10kHz, power: 80-500kW
- Melting metals furnaces MFS, frequency: 0,5-10kHz, power: 70-200kW
- Generators UHT, frequency: 200-400kHz, power: 10-160kW
- Go to the subcategory
- Lamp generators for induction heating
- Induction Heating Products - Himmelwerk
- Go to the subcategory
-
Induction Heating Products Ambrell
- Repairs and modernization
- Peripherals
-
Applications
- Medical Applications with Precision Induction Heating
- Applications for automotive industry
- Soldering
- Brazing
- Aluminum Brazing
- Brazing a magnetic steel cutting tool
- Pin Sealing
- Atmospheric Brazing
- Soldering brass and steel radiator caps
- Carbide Tipping
- Soldering a copper lug and a wire
- Go to the subcategory
- Knowledge base
- View all categories
-
Induction heating generators
-
-
-
Service
-
- Contact
- Zobacz wszystkie kategorie
Photos are for informational purposes only. View product specification
please use latin characters
Type | IF(AV)/TC [A/°C] | URRM [V] | IFSM [A] | I2t [A2s] | Rthjc [°C/W] | Torque Force | Casing Drawing number: |
---|---|---|---|---|---|---|---|
D22-10(R) | 10/105 | 100-1600 | 190 | 180 | 2 | 1,2-1,5 | 1 |
D32-32(R) | 32/100 | 100-1400 | 500 | 1250 | 0,9 | 2,0-2,5 | 2 |
D42-40(R) | 40/95 | 100-1400 | 600 | 1800 | 0,9 | Nm | |
D52-100(R) | 100/140 | 400-1200 | 2100 | 22000 | 0,25 | 14-17 | 3,4 |
100/125 | 1400-1600 | Nm | |||||
D51-100(R) | 100/125 | 1800-2000 | |||||
D52-150(R) | 150/120 | 400-1200 | 2700 | 36000 | 0,25 | 14-17 | |
150/105 | 1400-1600 | Nm | |||||
D52-200(R) | 200/110 | 400-1200 | 2900 | 42000 | 0,25 | 14-17 | |
200/95 | 1400-1600 | 2900 | 42000 | 0,25 | 14-17 | ||
D62-200(R); D66-200(R) | 200/140 | 400-1200 | 5000 | 125000 | 0,17 | 28-32 | 5,6 |
200/125 | 1400-1600 | Nm | |||||
D61-200(R); D64-200(R) | 200/125 | 1800-3200 | |||||
D62-250(R); D66-250(R) | 250/130 | 400-1200 | 5500 | 150000 | |||
250/115 | 1400-1600 | ||||||
D61-250(R); D64-250(R) | 250/115 | 1800-3200 | |||||
D62-300(R); D66-300(R) | 300/125 | 400-1200 | 6300 | 198000 | 0,15 | ||
300/110 | 1400-1600 | ||||||
D61-300(R); D64-300(R) | 300/115 | 1800-2000 | |||||
D71-300(R); D74-300(R) | 300/115 | 2000-4000 | 6300 | 200000 | 0,12 | 38-41 | 7 |
D71-450(R); D74-450(R) | 450/115 | 400-1200 | 7700 | 300000 | 0,12 | Nm | |
450/100 | 1400-3200 | ||||||
D71-600(R); D74-600(R) | 600/100 | 400-1200 | 9000 | 405000 | 0,12 | ||
D63-300 | 300/140 | 400-1200 | 5000 | 125000 | 0,095 | 4,5-6,2 | 9 |
300/125 | 1400-3000 | kN | |||||
D63-400 | 400/125 | 400-1200 | 5500 | 150000 | |||
400/110 | 1400-3000 | ||||||
D73-500 | 500/115 | 2000-4400 | 6400 | 204000 | 0,07 | 9-11 | 10 |
D73-800 | 800/95 | 400-1200 | 7700 | 30000 | kN | ||
800/80 | 1400-3200 | ||||||
D75-1100 | 1100/75 | 1400-2400 | 9000 | 405000 | 0,04 | 9-11 | 11 |
D75-1400 | 1400/75 | 400-1200 | 11000 | 605000 | kN | ||
D83-1000 | 1000/65 | 400-4400 | 11400 | 650000 | 0,037 | 12-14 | 10 |
D83-1200 | 1200/85 | 400-3200 | 14800 | 1090000 | kN | ||
D83-1400 | 1400/70 | 400-800 | 15800 | 1250000 | |||
D95-1600 | 1600/85 | 3000-4400 | 17000 | 1440000 | 0,023 | 22,5-25 | 12 |
D95-1800 | 1800/120 | 400-2000 | 19600 | 1920000 | kN | ||
1800/105 | 2200-3200 | ||||||
D95-2200 | 2200/100 | 1400-1600 | 23000 | 2640000 | |||
D95-3000 | 3000/90 | 200-1200 | 25000 | 3120000 |
Drawing 1 | Drawing 2 | Drawing 3 | Drawing 4 |
D22, R22 | D32, R32, D42 | D51, R51, D52, R52 | D51, R51, D52, R52...X1 |
Drawing 5 | Drawing 6 | ||
D61, R61, D62, R62 | D64, D66 | ||
Drawing 7 | Drawing 8 | ||
D71 | D74 | ||
Drawing 9 | Drawing 10 | Drawing 11 | Drawing 12 |
D63, R63 | D73, R73, D83, R83 | D75, R75 | D95, R95 |
Send an inquiry
Are you interested in this product? Do you need additional information or individual pricing?
Contact us
Type | IF(AV)/TC [A/°C] | URRM [V] | IFSM [A] | I2t [A2s] | Rthjc [°C/W] | Torque Force | Casing Drawing number: |
---|---|---|---|---|---|---|---|
D22-10(R) | 10/105 | 100-1600 | 190 | 180 | 2 | 1,2-1,5 | 1 |
D32-32(R) | 32/100 | 100-1400 | 500 | 1250 | 0,9 | 2,0-2,5 | 2 |
D42-40(R) | 40/95 | 100-1400 | 600 | 1800 | 0,9 | Nm | |
D52-100(R) | 100/140 | 400-1200 | 2100 | 22000 | 0,25 | 14-17 | 3,4 |
100/125 | 1400-1600 | Nm | |||||
D51-100(R) | 100/125 | 1800-2000 | |||||
D52-150(R) | 150/120 | 400-1200 | 2700 | 36000 | 0,25 | 14-17 | |
150/105 | 1400-1600 | Nm | |||||
D52-200(R) | 200/110 | 400-1200 | 2900 | 42000 | 0,25 | 14-17 | |
200/95 | 1400-1600 | 2900 | 42000 | 0,25 | 14-17 | ||
D62-200(R); D66-200(R) | 200/140 | 400-1200 | 5000 | 125000 | 0,17 | 28-32 | 5,6 |
200/125 | 1400-1600 | Nm | |||||
D61-200(R); D64-200(R) | 200/125 | 1800-3200 | |||||
D62-250(R); D66-250(R) | 250/130 | 400-1200 | 5500 | 150000 | |||
250/115 | 1400-1600 | ||||||
D61-250(R); D64-250(R) | 250/115 | 1800-3200 | |||||
D62-300(R); D66-300(R) | 300/125 | 400-1200 | 6300 | 198000 | 0,15 | ||
300/110 | 1400-1600 | ||||||
D61-300(R); D64-300(R) | 300/115 | 1800-2000 | |||||
D71-300(R); D74-300(R) | 300/115 | 2000-4000 | 6300 | 200000 | 0,12 | 38-41 | 7 |
D71-450(R); D74-450(R) | 450/115 | 400-1200 | 7700 | 300000 | 0,12 | Nm | |
450/100 | 1400-3200 | ||||||
D71-600(R); D74-600(R) | 600/100 | 400-1200 | 9000 | 405000 | 0,12 | ||
D63-300 | 300/140 | 400-1200 | 5000 | 125000 | 0,095 | 4,5-6,2 | 9 |
300/125 | 1400-3000 | kN | |||||
D63-400 | 400/125 | 400-1200 | 5500 | 150000 | |||
400/110 | 1400-3000 | ||||||
D73-500 | 500/115 | 2000-4400 | 6400 | 204000 | 0,07 | 9-11 | 10 |
D73-800 | 800/95 | 400-1200 | 7700 | 30000 | kN | ||
800/80 | 1400-3200 | ||||||
D75-1100 | 1100/75 | 1400-2400 | 9000 | 405000 | 0,04 | 9-11 | 11 |
D75-1400 | 1400/75 | 400-1200 | 11000 | 605000 | kN | ||
D83-1000 | 1000/65 | 400-4400 | 11400 | 650000 | 0,037 | 12-14 | 10 |
D83-1200 | 1200/85 | 400-3200 | 14800 | 1090000 | kN | ||
D83-1400 | 1400/70 | 400-800 | 15800 | 1250000 | |||
D95-1600 | 1600/85 | 3000-4400 | 17000 | 1440000 | 0,023 | 22,5-25 | 12 |
D95-1800 | 1800/120 | 400-2000 | 19600 | 1920000 | kN | ||
1800/105 | 2200-3200 | ||||||
D95-2200 | 2200/100 | 1400-1600 | 23000 | 2640000 | |||
D95-3000 | 3000/90 | 200-1200 | 25000 | 3120000 |
Drawing 1 | Drawing 2 | Drawing 3 | Drawing 4 |
D22, R22 | D32, R32, D42 | D51, R51, D52, R52 | D51, R51, D52, R52...X1 |
Drawing 5 | Drawing 6 | ||
D61, R61, D62, R62 | D64, D66 | ||
Drawing 7 | Drawing 8 | ||
D71 | D74 | ||
Drawing 9 | Drawing 10 | Drawing 11 | Drawing 12 |
D63, R63 | D73, R73, D83, R83 | D75, R75 | D95, R95 |
Related articles
-
Dioda prostownicza – jak działa, gdzie się je stosuje, budowa.Bardzo popularnym rodzajem diod o bardzo szerokim zastosowaniu są diody prostownicze, których zadaniem jest...Read more