Category
Photos are for informational purposes only. View product specification
please use latin characters
The SB08 pass-through current transformer can be used in measurement, protection, and energy metering applications. The product has a bore diameter matched to cables used in enclosed high-voltage switchgear and power transformers. The transformer design allows use in oil insulation environments (up to 105°C), air, nitrogen, and SF6. On request, the product can be equipped with a compensating winding, which protects the measurement from the influence of strong external magnetic fields originating, for example, from large currents flowing in adjacent phases. The transformer can be used independently or as a component of a larger device. More information on this topic is available in the component brochure.
| Operating Environment | Transformer oil (up to 105°C), air, nitrogen, SF6 |
|---|---|
| Standard | IEC61869-2, IEEE C57.13, CAN/CSA-C60044-1-07, AS60044.1 and others on request |
| Rated Primary Current (I1) | 30….30000A |
| Rated Secondary Current (I2) | 1.5A and others on request |
| Rated Burden | According to customer requirements e.g., 2.5, 5, 10, 15, 30VA |
| Accuracy Class | According to customer requirements e.g., 0.2S, 5P20, PX, TPY, C800 |
| Rated Short-Time Thermal Current | 100 x I1, max. 125kA |
| Rated Insulation Level | 0.72/3/-kV |
| Rated Frequency | According to customer requirements e.g., 50-60Hz, 16.7Hz |
| Secondary Wires | 4 or 6mm², l = 1.5m color-coded |
| Minimum Inner Diameter | ≥ 50mm |
| Maximum Allowable Outer Diameter | ≤ 1800mm |
| Maximum Allowable Height | ≤ 750mm |
| Maximum Weight | ≤ 600kg |


Discover the SB08 toroidal current transformer, ideal for current measurement, protection systems, and energy metering applications. The product features high measurement accuracy and a design that allows seamless integration with existing power installations.
The SB08 transformer has a bore diameter matched to standard conductors used in enclosed high-voltage switchgear and power transformers, facilitating installation in industrial systems. The device design allows operation in various insulating environments depending on the version: oil (up to 105°C), air, or gas (e.g., SF₆ or nitrogen).
Are you interested in this product? Do you need additional information or individual pricing?
The SB08 pass-through current transformer can be used in measurement, protection, and energy metering applications. The product has a bore diameter matched to cables used in enclosed high-voltage switchgear and power transformers. The transformer design allows use in oil insulation environments (up to 105°C), air, nitrogen, and SF6. On request, the product can be equipped with a compensating winding, which protects the measurement from the influence of strong external magnetic fields originating, for example, from large currents flowing in adjacent phases. The transformer can be used independently or as a component of a larger device. More information on this topic is available in the component brochure.
| Operating Environment | Transformer oil (up to 105°C), air, nitrogen, SF6 |
|---|---|
| Standard | IEC61869-2, IEEE C57.13, CAN/CSA-C60044-1-07, AS60044.1 and others on request |
| Rated Primary Current (I1) | 30….30000A |
| Rated Secondary Current (I2) | 1.5A and others on request |
| Rated Burden | According to customer requirements e.g., 2.5, 5, 10, 15, 30VA |
| Accuracy Class | According to customer requirements e.g., 0.2S, 5P20, PX, TPY, C800 |
| Rated Short-Time Thermal Current | 100 x I1, max. 125kA |
| Rated Insulation Level | 0.72/3/-kV |
| Rated Frequency | According to customer requirements e.g., 50-60Hz, 16.7Hz |
| Secondary Wires | 4 or 6mm², l = 1.5m color-coded |
| Minimum Inner Diameter | ≥ 50mm |
| Maximum Allowable Outer Diameter | ≤ 1800mm |
| Maximum Allowable Height | ≤ 750mm |
| Maximum Weight | ≤ 600kg |


Discover the SB08 toroidal current transformer, ideal for current measurement, protection systems, and energy metering applications. The product features high measurement accuracy and a design that allows seamless integration with existing power installations.
The SB08 transformer has a bore diameter matched to standard conductors used in enclosed high-voltage switchgear and power transformers, facilitating installation in industrial systems. The device design allows operation in various insulating environments depending on the version: oil (up to 105°C), air, or gas (e.g., SF₆ or nitrogen).
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent