Category
Photos are for informational purposes only. View product specification
please use latin characters
Medium voltage current transformers CTM 20 are key devices in power systems, enabling precise current measurements in medium voltage lines. They are used for monitoring and protecting power grids, transforming high currents into lower values that can be safely measured and analyzed.
Operating voltage (max.) | 17.5 kV - 24 kV |
Rated impulse voltage (1 min) | 38 kV - 50 kV |
Rated test voltage (1.2/50µs) | 95 kV - 125 kV |
Operating frequency | 50 Hz, 60 Hz |
Rated primary current | 10 A - 4000 A |
Primary connection | 2 x 10 A - 2 x 600 A |
Rated secondary current | 1 A, 5 A |
Maximum number of secondary windings | 4 |
Rated thermal current Ith (1s) | max. 60 kA (max. 2000 x In) |
Rated dynamic current | 2.5 x Ith, max. 120 kA |
Short-term load (mechanical) | 5000 N |
Insulation class | E |
Ambient temperature | -5… +40°C |
Mounting height (max.) | 1000 m |
Standard | IEC, VDE, ANSI |
Weight (approx.) | 16 kg - 20 kg |
Other parameter requirements and enclosure dimensions can be customized upon request. Also, check out other medium voltage current transformers!
Are you interested in this product? Do you need additional information or individual pricing?
Medium voltage current transformers CTM 20 are key devices in power systems, enabling precise current measurements in medium voltage lines. They are used for monitoring and protecting power grids, transforming high currents into lower values that can be safely measured and analyzed.
Operating voltage (max.) | 17.5 kV - 24 kV |
Rated impulse voltage (1 min) | 38 kV - 50 kV |
Rated test voltage (1.2/50µs) | 95 kV - 125 kV |
Operating frequency | 50 Hz, 60 Hz |
Rated primary current | 10 A - 4000 A |
Primary connection | 2 x 10 A - 2 x 600 A |
Rated secondary current | 1 A, 5 A |
Maximum number of secondary windings | 4 |
Rated thermal current Ith (1s) | max. 60 kA (max. 2000 x In) |
Rated dynamic current | 2.5 x Ith, max. 120 kA |
Short-term load (mechanical) | 5000 N |
Insulation class | E |
Ambient temperature | -5… +40°C |
Mounting height (max.) | 1000 m |
Standard | IEC, VDE, ANSI |
Weight (approx.) | 16 kg - 20 kg |
Other parameter requirements and enclosure dimensions can be customized upon request. Also, check out other medium voltage current transformers!
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent