Air dry lacquers - anti-flame - protective and for finish G141, G142, G144T, G145
  • Air dry lacquers - anti-flame - protective and for finish G141, G142, G144T, G145

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: SEG

Sneading varnishes on air flammable-protective and finishing G141, G142, G144T, G145

Application:
- winding protection,
- electro technical devices
- dry transformers.

Main characteristics:
- coloured lacquer, they have excellent protection preferences. 
      -for class B-G 141,
      - for class F- G 142 - G 145,
- those lacquers have advantage, that they dry in air
- soft drying at 80°C make fast polymerisation.
- lacquer G 144 T is often used as end lacquer in dry transformers,
- those lacquers exists in tropical execution as: G 141 T - G 142 T - G 144 T - G 145 T.

Impregnation:
By brush, immersion or pistol after giving 5-10%  diluent. .

Polymerisation (see table):
Possibility to dry in temperature 80 -100°C,a.
In case putting several layers it is obligatory do dry previous layer first. If we want to obtain good resistance for diluents, salt fog, or chemicals it is we must dry it for 2 hours in temperature 130°C.

Storage conditions:
Six months in original and closed package, hidden from the sun or any heat source.

Packing:
Containers 1, 5, 30 l or spray.

Hygiene and protection:
Lacquer G 142 consists ksylen.

 

Characteristic    G 144T G 142 G 145
Chemical origins gliceroftalowe modified alkyds modified alkyds
Thermal class B F F
pseudo-viscosity
NFT 30,014 section 4 @ 20°C
165s±30 250s±30 250s±30
density @ 20°C NFT 30,020 1,14 1,16 1,11
Dry extract NFT 30,011 63 ±2 60 ±2 60 ±2
Ignition point  NFT 30,050 34°C 26°C 34°C
Colour black red red, white, blue
Drying on a plate @ 20°C 5h 15h 5h
Drying on a coil @ 20°C 8h 24h 6h
Diluent 37004 37022 37004
Marking

 

Dielectric preferences

Breakdown voltage on a plate
(lacquer thickness 0,01 mm)
[V]
Natural state 700 900 1400 700
After 8 days;in humid air 500 680 1200 500
After 8 days;in destilated water 450 660 1200 450
After 8 days;in transformer oil 800 1000 1500 800

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

Application:
- winding protection,
- electro technical devices
- dry transformers.

Main characteristics:
- coloured lacquer, they have excellent protection preferences. 
      -for class B-G 141,
      - for class F- G 142 - G 145,
- those lacquers have advantage, that they dry in air
- soft drying at 80°C make fast polymerisation.
- lacquer G 144 T is often used as end lacquer in dry transformers,
- those lacquers exists in tropical execution as: G 141 T - G 142 T - G 144 T - G 145 T.

Impregnation:
By brush, immersion or pistol after giving 5-10%  diluent. .

Polymerisation (see table):
Possibility to dry in temperature 80 -100°C,a.
In case putting several layers it is obligatory do dry previous layer first. If we want to obtain good resistance for diluents, salt fog, or chemicals it is we must dry it for 2 hours in temperature 130°C.

Storage conditions:
Six months in original and closed package, hidden from the sun or any heat source.

Packing:
Containers 1, 5, 30 l or spray.

Hygiene and protection:
Lacquer G 142 consists ksylen.

 

Characteristic    G 144T G 142 G 145
Chemical origins gliceroftalowe modified alkyds modified alkyds
Thermal class B F F
pseudo-viscosity
NFT 30,014 section 4 @ 20°C
165s±30 250s±30 250s±30
density @ 20°C NFT 30,020 1,14 1,16 1,11
Dry extract NFT 30,011 63 ±2 60 ±2 60 ±2
Ignition point  NFT 30,050 34°C 26°C 34°C
Colour black red red, white, blue
Drying on a plate @ 20°C 5h 15h 5h
Drying on a coil @ 20°C 8h 24h 6h
Diluent 37004 37022 37004
Marking

 

Dielectric preferences

Breakdown voltage on a plate
(lacquer thickness 0,01 mm)
[V]
Natural state 700 900 1400 700
After 8 days;in humid air 500 680 1200 500
After 8 days;in destilated water 450 660 1200 450
After 8 days;in transformer oil 800 1000 1500 800