DHR 100 C10 current transducer
DHR 100 C10 current transducer

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: LEM

DHR 100 C10 current transducer

  • DHR 100 C10
  • Accuracy 1,00%
  • Rated Current [A] 100
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] 20...50V DC
  • Mounting [THT / SMD / DIN / Panel / On primary rail] Panel
  • App Automation/Drives/Power Supplies/Renewable Energy
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -40
  • Maximum operating temperature [°C] 70
  • Frequency response (-3dB) [kHz] 6
  • Feedback loop [open / closed] // Eta technology open

Applications:

  • VFD-controlled loads
    The VFD output indicates how the motor and connected load are operating.
  • SCR-controlled loads
    Accurately measure firing angles or firing pulses (proportional to time) of SCRs. Current measurement provides a faster response than temperature measurement.
  • Switched-mode power supplies and electronic ballasts
    True RMS measurement is the most accurate way to measure the input power of a power supply or ballast.

Technical specifications:

Measured quantity Current
Rated current 100A
Measuring range 600A
Output signal DC RMS voltage 0-10V
Signal Primary AC
Power Supply Not Required
Accuracy 1.5%
Operating Temperature -20°C…60°C
Technology Current Transformer
Mounting On Primary Busbar
971.70 PLN
971.70 PLN Gross price / pcs.
790.00 PLN Net price / pc.
Tax included

Availability: Please be advised that this product is out of stock

You can place a pre-order, report your interest in the product by clicking the "Ask for availability" button.

Out of stock
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

  • Accuracy 1,00%
  • Rated Current [A] 100
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] 20...50V DC
  • Mounting [THT / SMD / DIN / Panel / On primary rail] Panel
  • App Automation/Drives/Power Supplies/Renewable Energy
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -40
  • Maximum operating temperature [°C] 70
  • Frequency response (-3dB) [kHz] 6
  • Feedback loop [open / closed] // Eta technology open

Applications:

  • VFD-controlled loads
    The VFD output indicates how the motor and connected load are operating.
  • SCR-controlled loads
    Accurately measure firing angles or firing pulses (proportional to time) of SCRs. Current measurement provides a faster response than temperature measurement.
  • Switched-mode power supplies and electronic ballasts
    True RMS measurement is the most accurate way to measure the input power of a power supply or ballast.

Technical specifications:

Measured quantity Current
Rated current 100A
Measuring range 600A
Output signal DC RMS voltage 0-10V
Signal Primary AC
Power Supply Not Required
Accuracy 1.5%
Operating Temperature -20°C…60°C
Technology Current Transformer
Mounting On Primary Busbar
Comments (0)