HXN 03-P current transducer
HXN 03-P current transducer

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: LEM

HXN 03-P current transducer

  • HXN 03-P
  • Accuracy 1
  • Rated Current [A] 3
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] ±15
  • Mounting [THT / SMD / DIN / Panel / On primary rail] THT
  • App Drives/Power Supplies/Renewable Energy/Welding
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -25
  • Maximum operating temperature [°C] 85
  • Frequency response (-3dB) [kHz] 50
  • Feedback loop [open / closed] // Eta technology open

Description

Designed for electronic current measurement: DC, AC, pulsed, etc., with galvanic isolation between the primary and secondary circuits.

Main Features

  • Measurement based on the Hall effect
  • Low power consumption
  • Insulating plastic housing compliant with UL 94-V0
  • Low insertion losses
  • Easy installation with automatic handling system
  • Small size to save space
  • Only one design for a wide range of rated currents
  • High immunity to external interference

Applications

  • Variable speed AC drives and Servomotors
  • Static Converters for DC Motor Drives
  • Battery-Powered Applications
  • Uninterruptible Power Supplies (UPS)
  • Switched-Mode Power Supplies (SMPS)
  • Electrical Devices

Technical Data

Parameter Value
Rated RMS Primary Current (IPN) 3A
Primary Current Measuring Range (IPM) ±9A
Primary Wire Diameter x Turns (mm) 0.6d x 20T
Output Voltage (Analog) for ±Ipn, RL=10kΩ, TA=25°C ±4V
Output Internal Resistance < 50Ω
Load Resistance ≥ 10kΩ
Supply Voltage (±5%) ±15V
Current consumption < ±15mA
Error at primary current Ipn and temperature TA=25°C (without offset) < ±1%· IPN
Frequency response (-3dB) DC…50kHz
Operating temperature -25÷85°C
Temperature storage -25÷85°C
Weight < 8g

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

  • Accuracy 1
  • Rated Current [A] 3
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] ±15
  • Mounting [THT / SMD / DIN / Panel / On primary rail] THT
  • App Drives/Power Supplies/Renewable Energy/Welding
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -25
  • Maximum operating temperature [°C] 85
  • Frequency response (-3dB) [kHz] 50
  • Feedback loop [open / closed] // Eta technology open

Description

Designed for electronic current measurement: DC, AC, pulsed, etc., with galvanic isolation between the primary and secondary circuits.

Main Features

  • Measurement based on the Hall effect
  • Low power consumption
  • Insulating plastic housing compliant with UL 94-V0
  • Low insertion losses
  • Easy installation with automatic handling system
  • Small size to save space
  • Only one design for a wide range of rated currents
  • High immunity to external interference

Applications

  • Variable speed AC drives and Servomotors
  • Static Converters for DC Motor Drives
  • Battery-Powered Applications
  • Uninterruptible Power Supplies (UPS)
  • Switched-Mode Power Supplies (SMPS)
  • Electrical Devices

Technical Data

Parameter Value
Rated RMS Primary Current (IPN) 3A
Primary Current Measuring Range (IPM) ±9A
Primary Wire Diameter x Turns (mm) 0.6d x 20T
Output Voltage (Analog) for ±Ipn, RL=10kΩ, TA=25°C ±4V
Output Internal Resistance < 50Ω
Load Resistance ≥ 10kΩ
Supply Voltage (±5%) ±15V
Current consumption < ±15mA
Error at primary current Ipn and temperature TA=25°C (without offset) < ±1%· IPN
Frequency response (-3dB) DC…50kHz
Operating temperature -25÷85°C
Temperature storage -25÷85°C
Weight < 8g