LAS 100-P current transducer
LAS 100-P current transducer

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: LEM

LAS 100-P current transducer

  • LAS 100-P
  • Accuracy 1
  • Rated Current [A] 100
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] 5
  • Mounting [THT / SMD / DIN / Panel / On primary rail] THT
  • App Drives/Power Supplies/Renewable Energy/Welding
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -40
  • Maximum operating temperature [°C] 85
  • Frequency response (-3dB) [kHz] 100
  • Feedback loop [open / closed] // Eta technology Eta

LA 100-P Current Transducer

For electronic measurement of currents: direct, alternating, pulsed..., with galvanic isolation between primary and secondary circuits.

Features

  • Closed-loop (compensated) current transducer using the Hall effect
  • Insulated plastic housing compliant with UL 94-V0.

Advantages

  • Excellent accuracy
  • Very good linearity
  • Low temperature variation
  • Optimal response time
  • Wide frequency band
  • No insertion losses
  • High interference immunity External
  • Possibility of current overload.

Applications

  • AC variable speed drives and servo motor drives
  • Static converters for DC motor drives
  • Battery-powered applications
  • Uninterruptible power supplies (UPS)
  • Switched-mode power supplies (SMPS)
  • Power supplies for welding applications
Series LA100P
Measurements Current
Nominal Value 100 A
Measuring Range 150 A
Secondary Nominal Signal Current
Secondary Nominal Signal Value Instantaneous 50 mA
Signal Primary AC + DC
Supply Voltage External DC Bipolar
Supply Voltage Range 12 - 15 V
Accuracy 0.45 %
Operating Temperature -40 °C / 85 °C
Technology Hall Effect in a Closed Circuit loop
Assembly PCB
Applications Drives, Power Supplies, Renewable Energy Sources, Welding

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

  • Accuracy 1
  • Rated Current [A] 100
  • Primary signal [AC / AC+DC / DC] AC+DC
  • Supply voltage [V] 5
  • Mounting [THT / SMD / DIN / Panel / On primary rail] THT
  • App Drives/Power Supplies/Renewable Energy/Welding
  • Output signal type [current/voltage] voltage
  • Minimum operating temperature [°C] -40
  • Maximum operating temperature [°C] 85
  • Frequency response (-3dB) [kHz] 100
  • Feedback loop [open / closed] // Eta technology Eta

LA 100-P Current Transducer

For electronic measurement of currents: direct, alternating, pulsed..., with galvanic isolation between primary and secondary circuits.

Features

  • Closed-loop (compensated) current transducer using the Hall effect
  • Insulated plastic housing compliant with UL 94-V0.

Advantages

  • Excellent accuracy
  • Very good linearity
  • Low temperature variation
  • Optimal response time
  • Wide frequency band
  • No insertion losses
  • High interference immunity External
  • Possibility of current overload.

Applications

  • AC variable speed drives and servo motor drives
  • Static converters for DC motor drives
  • Battery-powered applications
  • Uninterruptible power supplies (UPS)
  • Switched-mode power supplies (SMPS)
  • Power supplies for welding applications
Series LA100P
Measurements Current
Nominal Value 100 A
Measuring Range 150 A
Secondary Nominal Signal Current
Secondary Nominal Signal Value Instantaneous 50 mA
Signal Primary AC + DC
Supply Voltage External DC Bipolar
Supply Voltage Range 12 - 15 V
Accuracy 0.45 %
Operating Temperature -40 °C / 85 °C
Technology Hall Effect in a Closed Circuit loop
Assembly PCB
Applications Drives, Power Supplies, Renewable Energy Sources, Welding