Category
Photos are for informational purposes only. View product specification
please use latin characters

• Photovoltaic surge protector panel
• UTE C15-712-1 compliance
• AC network connection
• Line and differential circuit-breaker
| CITEL part number |
CPV240-230-xxx-DDR |
|
|---|---|---|
| Network tension | Un | 230 V mono |
| Maximum current | 16 A - 25 A - 32 A | |
| Network connection (intput/output) | 6 mm2 max. | |
| Security | ||
| Thermal disconnector | internaL | |
| Visualization of disconnection | indicator Lightning | |
| Surge protector | branch circuit breaker in surge protector | |
| Overcurrent protection | by Line circuit breaker [catibre 16 or 32 A) | |
| Protection against indirect contacts | by differentiaL circuit breaker 30mA | |
| Type 2 surge protector | DS240-230/G | |
| Max. operating vottage | Uc | 255 Vac |
| Nominał discharge current | In | 20 kA |
| Max. discharge current | Imax | 40 kA |
| Protection LeveL (CM/DM) | Up | 1,5/1,25 kV |
| Characteristics case | ||
| Protection LeveL | IP 55 | |
| Dimensions (H x L x P) mm | 198 x 255 x 108 | |
| Enclosure materiał | PoLycarbonate UL 94VO | |
| Access equipment | Transparente door | |
| Shift cabLe | by cabLe gLands | |

• 3 string surge protector panel
• 500, 600 and 800 Vdc
• Max. current : 25 A
• Sectionnement
| CITEL part number |
CPV50-500-40A-3ST |
CPV50-600-40A-3ST |
CPV50-800-40A-3ST |
|
|---|---|---|---|---|
| Number of strings | 3 | 3 | 3 | |
| Max. PV voLtage | Uocstc | 500 Vdc | 600 Vdc | 800 Vdc |
| Max. PV current | Imppstc | 25 A | 25 A | 25 A |
| Network connection (input/outputl | terminal 6,5/10 mm2 | terminaL 6,5/10 mm2 | terminaL 6,5/10 mm2 | |
| DC switch | yes | yes | yes | |
| Fuses protection by strings | option | option | option | |
| Type 2 surge protector | DS50PV-500/51 | DS50PV-600/51 | DS50PV-800/51 | |
| Max. PV voLtage | Ucpv | 600 Vdc | 720 Vdc | 960 Vdc |
| Nom. discharge current | In | 15 kA | 15 kA | 15 kA |
| Max. discharge current | Imax | 40 kA | 40 kA | 40 kA |
| Protection LeveL | Up | 2,2 kV | 2,8 kV | 2/3,6 kV |
| Characteristics case | ||||
| Protection LeveL | IP65 | |||
| Dimensions (HxLxP) | 305 x 225 x 125 mm | |||
| EncLosure materiaL | ABS PC | |||
| Type of handLe | externaL LockabLe | |||

• AC/DC combined surge protector panel
• Differential circuit breakers
• Disconnection and connection of PV modules
| CITEL part number |
CPV240-50-230-xx-DDR |
||
|---|---|---|---|
| Network | AC singLe phase network | 2 strings - DC network | |
| Network voltage | Un/Uocstc | 230 V mono | 600 Vdc |
| Max. current (xx) | 16A - 25A -32A | 25A | |
| Connection (inverter/networkj | 6 mm2 max. in screw terminat | 6mm2 max in terminaL resort type MC connector | |
| Security | |||
| ThermaL disconnector | internaL surge protector | internaL surge protector | |
| VisuaLization of disconnection | surge protector indicator | surge protector indicator | |
| Surge protector | SPDs breaker | not necessary | |
| Overcurrent protection | by Line circuit breaker | without | |
| Protection against indirect contacts | by diff. circuit breaker 30 mA | without | |
| Type 2 surge protector | DS240-230/G | DS50PV-600/51 | |
| Tension de regime permanent max. | Ucpv | 255 Vac | 720 Vdc |
| Nominał discharge current | In | 20 kA | 15 kA |
| Max. discharge current | Imax | 40 kA | 40 kA |
| Protection LeveL | Up | 1,5/1,25 kV | 2,8 kV |
| Characteristics case | |||
| Dimensions (H x L x P) | 420 x 298 x 140 mm | ||
| EncLosure materiaL | PoLycarbonate UL94 VD | ||
| Protection LeveL | IP55 | ||
| Access equipement | Transparent door | ||
| Shift cabLe | by cabLe gLands | ||
Are you interested in this product? Do you need additional information or individual pricing?

• Photovoltaic surge protector panel
• UTE C15-712-1 compliance
• AC network connection
• Line and differential circuit-breaker
| CITEL part number |
CPV240-230-xxx-DDR |
|
|---|---|---|
| Network tension | Un | 230 V mono |
| Maximum current | 16 A - 25 A - 32 A | |
| Network connection (intput/output) | 6 mm2 max. | |
| Security | ||
| Thermal disconnector | internaL | |
| Visualization of disconnection | indicator Lightning | |
| Surge protector | branch circuit breaker in surge protector | |
| Overcurrent protection | by Line circuit breaker [catibre 16 or 32 A) | |
| Protection against indirect contacts | by differentiaL circuit breaker 30mA | |
| Type 2 surge protector | DS240-230/G | |
| Max. operating vottage | Uc | 255 Vac |
| Nominał discharge current | In | 20 kA |
| Max. discharge current | Imax | 40 kA |
| Protection LeveL (CM/DM) | Up | 1,5/1,25 kV |
| Characteristics case | ||
| Protection LeveL | IP 55 | |
| Dimensions (H x L x P) mm | 198 x 255 x 108 | |
| Enclosure materiał | PoLycarbonate UL 94VO | |
| Access equipment | Transparente door | |
| Shift cabLe | by cabLe gLands | |

• 3 string surge protector panel
• 500, 600 and 800 Vdc
• Max. current : 25 A
• Sectionnement
| CITEL part number |
CPV50-500-40A-3ST |
CPV50-600-40A-3ST |
CPV50-800-40A-3ST |
|
|---|---|---|---|---|
| Number of strings | 3 | 3 | 3 | |
| Max. PV voLtage | Uocstc | 500 Vdc | 600 Vdc | 800 Vdc |
| Max. PV current | Imppstc | 25 A | 25 A | 25 A |
| Network connection (input/outputl | terminal 6,5/10 mm2 | terminaL 6,5/10 mm2 | terminaL 6,5/10 mm2 | |
| DC switch | yes | yes | yes | |
| Fuses protection by strings | option | option | option | |
| Type 2 surge protector | DS50PV-500/51 | DS50PV-600/51 | DS50PV-800/51 | |
| Max. PV voLtage | Ucpv | 600 Vdc | 720 Vdc | 960 Vdc |
| Nom. discharge current | In | 15 kA | 15 kA | 15 kA |
| Max. discharge current | Imax | 40 kA | 40 kA | 40 kA |
| Protection LeveL | Up | 2,2 kV | 2,8 kV | 2/3,6 kV |
| Characteristics case | ||||
| Protection LeveL | IP65 | |||
| Dimensions (HxLxP) | 305 x 225 x 125 mm | |||
| EncLosure materiaL | ABS PC | |||
| Type of handLe | externaL LockabLe | |||

• AC/DC combined surge protector panel
• Differential circuit breakers
• Disconnection and connection of PV modules
| CITEL part number |
CPV240-50-230-xx-DDR |
||
|---|---|---|---|
| Network | AC singLe phase network | 2 strings - DC network | |
| Network voltage | Un/Uocstc | 230 V mono | 600 Vdc |
| Max. current (xx) | 16A - 25A -32A | 25A | |
| Connection (inverter/networkj | 6 mm2 max. in screw terminat | 6mm2 max in terminaL resort type MC connector | |
| Security | |||
| ThermaL disconnector | internaL surge protector | internaL surge protector | |
| VisuaLization of disconnection | surge protector indicator | surge protector indicator | |
| Surge protector | SPDs breaker | not necessary | |
| Overcurrent protection | by Line circuit breaker | without | |
| Protection against indirect contacts | by diff. circuit breaker 30 mA | without | |
| Type 2 surge protector | DS240-230/G | DS50PV-600/51 | |
| Tension de regime permanent max. | Ucpv | 255 Vac | 720 Vdc |
| Nominał discharge current | In | 20 kA | 15 kA |
| Max. discharge current | Imax | 40 kA | 40 kA |
| Protection LeveL | Up | 1,5/1,25 kV | 2,8 kV |
| Characteristics case | |||
| Dimensions (H x L x P) | 420 x 298 x 140 mm | ||
| EncLosure materiaL | PoLycarbonate UL94 VD | ||
| Protection LeveL | IP55 | ||
| Access equipement | Transparent door | ||
| Shift cabLe | by cabLe gLands | ||
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent