Category
Photos are for informational purposes only. View product specification
please use latin characters
Current transformers with built-in transducers are innovative products that measure alternating current and provide a 4..20mA output, a standard for PLC controllers or other monitoring systems. A single enclosure contains the transformer, transducer, and a trimmer allowing adjustment of one of the available primary current ranges for the given model.
Advantages of this solution include:
Thus, transformers with transducers are measurement devices designed for precise monitoring of primary current in power systems and measurement systems. Thanks to the use of a core and primary and secondary windings, they allow measurement of high current levels with high accuracy, generating a DC or constant voltage output adapted to the standards of controllers and automation systems. They are used in industrial installations, low-voltage transformers, automation systems, and wherever accurate primary current measurement is required, e.g., up to 3000 A in accordance with standards and electromagnetic compatibility requirements.
Technical data
| Nominal current In | 5-6000A |
|---|---|
| Nominal value | 4-20 mA |
| See graph | 0-1100 Ω |
| From current loop | 10-32 Vdc |
| Accuracy class | 1 |
| Response time | <200msec |
| Reference frequency | 50 -60 Hz |
| Voltage | 0,72 kV |
| Test voltage | 3kV x 50Hz (60sek.) |
| Protection degree | IP 20 |
| Insulation | classe E |
| Operating temperature | -25 +50 oC |
| Storage temperature | -40 +50 oC |
| Integrated secondary terminals | 6 mm2 |
| Safety factor | N<5 |
| Rated dynamic current (I dyn) | 2.5 x I th |
| Manufactured according to | EN 60044-1 EN 60688 |
| Thermoplastic material | UL94-V0 |
| Chart | Wiring diagram |
![]() |
![]() |
| MULTIRANGE C.T. WITH 4-20mA OUTPUT |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| CODE |
MAC021XXXG42 |
MAC017XXXG42 |
MAC032XXXG42 |
MAC040XXXG42 |
M AT061XXXG42 |
MAT 101XXXG42 |
| CABLE | Ø 21 mm | Ø 17 mm | Ø 23 mm | Ø 32 mm | Ø 51 mm | |
| BAR DIM. | 20 x 10 mm | 15x5 mm | 32 x 10 mm | 40 x 10 mm | 61 x 31 mm | 101 x 55 mm |
| FIXING | D - 1 - P | D - 1 - P | D - I - P | D - I - P | I | I |
| C.T. WIDTH | 70 mm | 56 mm | 56 mm | 70 mm | 90 mm | 130 mm |
| MIN. INTERAXIS | 46 mm | 36,5 mm | 45 mm | 56 mm | 68 mm | 115 mm |
| PORTATE SELEZIONABILI- SELECTABLE RANGE | ||||||
|---|---|---|---|---|---|---|
| 5 A | • | |||||
| 6 A | • | |||||
| 7,5 A | • | |||||
| 10 A | • | |||||
| 15 A | • | |||||
| 20 A | • | • | ||||
| 25 A | • | |||||
| 30 A | • | • | ||||
| 40 A | • | |||||
| 50 A | • | • | ||||
| 60 A | • | • | ||||
| 75 A | • | |||||
| 80 A | • | |||||
| 100 A | • | • | • | |||
| 120 A | • | • | ||||
| 125 A | • | |||||
| 150 A | • | • | ||||
| 200 A | • | • | • | |||
| 250 A | • | • | ||||
| 300 A | • | • | • | |||
| 400 A | • | • | • | |||
| 500 A | • | • | ||||
| 600 A | • | • | • | |||
| 750 A | ||||||
| 800 A | • | • | ||||
| 1000 A | • | • | ||||
| 1200 A | • | • | ||||
| 1250 A | ||||||
| 1500 A | ||||||
| 1600 A | • | |||||
| 2000 A | • | |||||
| 2400 A | • | |||||
| 2500 A | ||||||
| 3000 A | ||||||
| 4000 A | ||||||
| 5000 A | ||||||
| 6000 A | ||||||
| MULTIRANGE C.T. WITH 4-20mA OUTPUT |
![]() |
![]() |
![]() |
![]() |
![]() |
| CODE |
MAT 127XXXG42 |
MAT 128XXXG42 |
MAT129XXXG42 |
MAT165XXXG42 |
MAT225XXXG42 |
| CABLE | |||||
| BAR DIM. | 127x 55 mm | 127 x 85 mm | 127 x 105 mm | 165 x 127 mm | 225 x 127 mm |
| FIXING | B | I | I | I | I |
| C.T. WIDTH | 185 mm | 185 mm | 185 mm | 308 mm | 368 mm |
| MIN. INTERAXIS | 156 mm | 156 mm | 156 mm | 238 mm | 298 mm |
| PORTATE SELEZIONABILI- SELECTABLE RANGE | |||||
|---|---|---|---|---|---|
| 5 A | |||||
| 6 A | |||||
| 7,5 A | |||||
| 10 A | |||||
| 15 A | |||||
| 20 A | |||||
| 25 A | |||||
| 30 A | |||||
| 40 A | |||||
| 50 A | |||||
| 60 A | |||||
| 75 A | |||||
| 80 A | |||||
| 100 A | |||||
| 120 A | |||||
| 125 A | |||||
| 150 A | |||||
| 200 A | |||||
| 250 A | |||||
| 300 A | |||||
| 400 A | |||||
| 500 A | • | ||||
| 600 A | • | ||||
| 750 A | • | ||||
| 800 A | |||||
| 1000 A | • | • | • | • | • |
| 1200 A | • | • | • | • | |
| 1250 A | • | ||||
| 1500 A | • | • | • | • | • |
| 1600 A | |||||
| 2000 A | • | • | • | • | • |
| 2400 A | |||||
| 2500 A | • | • | • | • | • |
| 3000 A | • | • | • | • | • |
| 4000 A | • | • | • | • | |
| 5000 A | • | • | • | • | |
| 6000 A | • | • | • | • | |
P = PIEDINI - FIXING FEETS
B = BRIGLIA ANCORAGGIO SU BARRA PRIMARIO - BUSBAR FIXING
D = BINARIO DIN EN 50022 - DIN RAIL EN50022
I = SISTEMA INTEGRATO - BUILT-IN FIXING SYSTEM
These transducers, with integrated current transformer, are suitable to measure the rms value of currents with sinusoidal undistorted waveforms or, for the TRMS types only, also with distorted waveforms; in this case the additional error is 0.5% for crest factor < 3 and 1% for crest factor < 7. The outputs are load independent d.c. current or voltage, propor-tional to the input variable.
Technical data
|
Outputs |
0-1mA(15kΩ); 0-5mA(3kΩ); 0-20mA(750Ω); 4-20mA (750Ω); 0-10V (>2kΩ) |
|---|---|
|
Aux. supply voltage |
115-230 Va.c 24V a.c; 48Va.c; 400Va.c; 24V d.c; 48V d.c; 110V d.c; 220Vd.c; 20-60Va.c/d.c; 80-260V a.c/d.c. |
| Accuracy class | 1 |
| Input range | 5..120% In |
| Response time | <200 ms |
| Continuous overload | 2x In |
| Short-term overloa | 20 x In |
| Reference frequency | 50-60 Hz |
| Operating temperature | -10 +50 oC |
| Storage temperature | -30 +70 oC |
| According to | EN 60688 |
| Thermoplastic material | UL94-V0 |
| Test voltage | 2kV, 50Hz, 60sec |
| Surge test | 5kV 1.2/50 µs |
| Chart | Wiring diagram |
![]() |
![]() |
| Range | RMS | TRMS |
|---|---|---|
| 5A |
MCOEAQ005 |
MCOEAR005 |
| 10A |
MCOEAQ010 |
MCOEAR010 |
| 15A |
MCOEAQ015 |
MCOEAR015 |
| 20A |
MCOEAQ020 |
MCOEAR020 |
| 25A |
MCOEAQ025 |
MCOEAR025 |
| 30A |
MCOEAQ030 |
MCOEAR030 |
| 40A |
MCOEAQ040 |
MCOEAR040 |
| 50A |
MCOEAQ050 |
MCOEAR050 |
| 60A |
MCOEAQ060 |
MCOEAR060 |
| 80A |
MCOEAQ080 |
MCOEAR080 |
| 100A |
MCOEAQ100 |
MCOEAR100 |
Are you interested in this product? Do you need additional information or individual pricing?
Current transformers with built-in transducers are innovative products that measure alternating current and provide a 4..20mA output, a standard for PLC controllers or other monitoring systems. A single enclosure contains the transformer, transducer, and a trimmer allowing adjustment of one of the available primary current ranges for the given model.
Advantages of this solution include:
Thus, transformers with transducers are measurement devices designed for precise monitoring of primary current in power systems and measurement systems. Thanks to the use of a core and primary and secondary windings, they allow measurement of high current levels with high accuracy, generating a DC or constant voltage output adapted to the standards of controllers and automation systems. They are used in industrial installations, low-voltage transformers, automation systems, and wherever accurate primary current measurement is required, e.g., up to 3000 A in accordance with standards and electromagnetic compatibility requirements.
Technical data
| Nominal current In | 5-6000A |
|---|---|
| Nominal value | 4-20 mA |
| See graph | 0-1100 Ω |
| From current loop | 10-32 Vdc |
| Accuracy class | 1 |
| Response time | <200msec |
| Reference frequency | 50 -60 Hz |
| Voltage | 0,72 kV |
| Test voltage | 3kV x 50Hz (60sek.) |
| Protection degree | IP 20 |
| Insulation | classe E |
| Operating temperature | -25 +50 oC |
| Storage temperature | -40 +50 oC |
| Integrated secondary terminals | 6 mm2 |
| Safety factor | N<5 |
| Rated dynamic current (I dyn) | 2.5 x I th |
| Manufactured according to | EN 60044-1 EN 60688 |
| Thermoplastic material | UL94-V0 |
| Chart | Wiring diagram |
![]() |
![]() |
| MULTIRANGE C.T. WITH 4-20mA OUTPUT |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| CODE |
MAC021XXXG42 |
MAC017XXXG42 |
MAC032XXXG42 |
MAC040XXXG42 |
M AT061XXXG42 |
MAT 101XXXG42 |
| CABLE | Ø 21 mm | Ø 17 mm | Ø 23 mm | Ø 32 mm | Ø 51 mm | |
| BAR DIM. | 20 x 10 mm | 15x5 mm | 32 x 10 mm | 40 x 10 mm | 61 x 31 mm | 101 x 55 mm |
| FIXING | D - 1 - P | D - 1 - P | D - I - P | D - I - P | I | I |
| C.T. WIDTH | 70 mm | 56 mm | 56 mm | 70 mm | 90 mm | 130 mm |
| MIN. INTERAXIS | 46 mm | 36,5 mm | 45 mm | 56 mm | 68 mm | 115 mm |
| PORTATE SELEZIONABILI- SELECTABLE RANGE | ||||||
|---|---|---|---|---|---|---|
| 5 A | • | |||||
| 6 A | • | |||||
| 7,5 A | • | |||||
| 10 A | • | |||||
| 15 A | • | |||||
| 20 A | • | • | ||||
| 25 A | • | |||||
| 30 A | • | • | ||||
| 40 A | • | |||||
| 50 A | • | • | ||||
| 60 A | • | • | ||||
| 75 A | • | |||||
| 80 A | • | |||||
| 100 A | • | • | • | |||
| 120 A | • | • | ||||
| 125 A | • | |||||
| 150 A | • | • | ||||
| 200 A | • | • | • | |||
| 250 A | • | • | ||||
| 300 A | • | • | • | |||
| 400 A | • | • | • | |||
| 500 A | • | • | ||||
| 600 A | • | • | • | |||
| 750 A | ||||||
| 800 A | • | • | ||||
| 1000 A | • | • | ||||
| 1200 A | • | • | ||||
| 1250 A | ||||||
| 1500 A | ||||||
| 1600 A | • | |||||
| 2000 A | • | |||||
| 2400 A | • | |||||
| 2500 A | ||||||
| 3000 A | ||||||
| 4000 A | ||||||
| 5000 A | ||||||
| 6000 A | ||||||
| MULTIRANGE C.T. WITH 4-20mA OUTPUT |
![]() |
![]() |
![]() |
![]() |
![]() |
| CODE |
MAT 127XXXG42 |
MAT 128XXXG42 |
MAT129XXXG42 |
MAT165XXXG42 |
MAT225XXXG42 |
| CABLE | |||||
| BAR DIM. | 127x 55 mm | 127 x 85 mm | 127 x 105 mm | 165 x 127 mm | 225 x 127 mm |
| FIXING | B | I | I | I | I |
| C.T. WIDTH | 185 mm | 185 mm | 185 mm | 308 mm | 368 mm |
| MIN. INTERAXIS | 156 mm | 156 mm | 156 mm | 238 mm | 298 mm |
| PORTATE SELEZIONABILI- SELECTABLE RANGE | |||||
|---|---|---|---|---|---|
| 5 A | |||||
| 6 A | |||||
| 7,5 A | |||||
| 10 A | |||||
| 15 A | |||||
| 20 A | |||||
| 25 A | |||||
| 30 A | |||||
| 40 A | |||||
| 50 A | |||||
| 60 A | |||||
| 75 A | |||||
| 80 A | |||||
| 100 A | |||||
| 120 A | |||||
| 125 A | |||||
| 150 A | |||||
| 200 A | |||||
| 250 A | |||||
| 300 A | |||||
| 400 A | |||||
| 500 A | • | ||||
| 600 A | • | ||||
| 750 A | • | ||||
| 800 A | |||||
| 1000 A | • | • | • | • | • |
| 1200 A | • | • | • | • | |
| 1250 A | • | ||||
| 1500 A | • | • | • | • | • |
| 1600 A | |||||
| 2000 A | • | • | • | • | • |
| 2400 A | |||||
| 2500 A | • | • | • | • | • |
| 3000 A | • | • | • | • | • |
| 4000 A | • | • | • | • | |
| 5000 A | • | • | • | • | |
| 6000 A | • | • | • | • | |
P = PIEDINI - FIXING FEETS
B = BRIGLIA ANCORAGGIO SU BARRA PRIMARIO - BUSBAR FIXING
D = BINARIO DIN EN 50022 - DIN RAIL EN50022
I = SISTEMA INTEGRATO - BUILT-IN FIXING SYSTEM
These transducers, with integrated current transformer, are suitable to measure the rms value of currents with sinusoidal undistorted waveforms or, for the TRMS types only, also with distorted waveforms; in this case the additional error is 0.5% for crest factor < 3 and 1% for crest factor < 7. The outputs are load independent d.c. current or voltage, propor-tional to the input variable.
Technical data
|
Outputs |
0-1mA(15kΩ); 0-5mA(3kΩ); 0-20mA(750Ω); 4-20mA (750Ω); 0-10V (>2kΩ) |
|---|---|
|
Aux. supply voltage |
115-230 Va.c 24V a.c; 48Va.c; 400Va.c; 24V d.c; 48V d.c; 110V d.c; 220Vd.c; 20-60Va.c/d.c; 80-260V a.c/d.c. |
| Accuracy class | 1 |
| Input range | 5..120% In |
| Response time | <200 ms |
| Continuous overload | 2x In |
| Short-term overloa | 20 x In |
| Reference frequency | 50-60 Hz |
| Operating temperature | -10 +50 oC |
| Storage temperature | -30 +70 oC |
| According to | EN 60688 |
| Thermoplastic material | UL94-V0 |
| Test voltage | 2kV, 50Hz, 60sec |
| Surge test | 5kV 1.2/50 µs |
| Chart | Wiring diagram |
![]() |
![]() |
| Range | RMS | TRMS |
|---|---|---|
| 5A |
MCOEAQ005 |
MCOEAR005 |
| 10A |
MCOEAQ010 |
MCOEAR010 |
| 15A |
MCOEAQ015 |
MCOEAR015 |
| 20A |
MCOEAQ020 |
MCOEAR020 |
| 25A |
MCOEAQ025 |
MCOEAR025 |
| 30A |
MCOEAQ030 |
MCOEAR030 |
| 40A |
MCOEAQ040 |
MCOEAR040 |
| 50A |
MCOEAQ050 |
MCOEAR050 |
| 60A |
MCOEAQ060 |
MCOEAR060 |
| 80A |
MCOEAQ080 |
MCOEAR080 |
| 100A |
MCOEAQ100 |
MCOEAR100 |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent