RCTrms Series
  • RCTrms Series

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: PEM

RCTrms Series

The RCTrms is an AC current transducer for permanent installation. Simple to install and easy to retrofit it combines the benefits of a thin, flexible, clip-around Rogowski (sense) coil with a signal conditioner providing accurate, true rms measurement, of AC current. The RCTrms has an industry standard 4-20mA output making it ideal for process control, status alarming or system monitoring purposes. Typically the RCTrms is used with SCADA systems, PLCs, data loggers and protection equipment.

Features:

  • Easy to retrofit
  • Simple to install in applications where space is limited
  • The size of the Rogowski coil can be specified independently of the primary current
  • Does not suffer from magnetic saturation
  • Intrinsically safe
  • Ideal for process control, status alarming or system monitoring in a wide variety of applications, from arc furnaces to power distribution 

Technical data:

  • Traceable calibration
    • Every unit is supplied with a traceable calibration certificate
    • No magnetic materials means excellent linearity <0.2% of reading
  • Fully isolated measurement
    • Isolated power supply 2kVdc
    • Coil rated at 2kVpeak (withstand test is 4kVrms / 50Hz/ 60 sec)
  • Small DIN rail (or panel mount) enclosure – UL94 V-0 rated
 

Options:

  • Isolated BNC-BNC cable split option
    - Between coil and electronics to enable ease of
    installation e.g. threading through existing conduit.
    Standard cable permanently fixed
  • IP65 die-cast aluminium panel mount enclosure
Rated current [Arms] 100, 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000,10000,16000, 20000, 25000, 40000, 50000
Rated output (Full scale FS)

4 ÷ 20mA

Output limit 150% FS (28mA)
Supply voltage (Wide input) 12Vdc (-10%) to 24Vdc (+20%)
Input power 0.7W (at rated output)
Operating temperature range -5°C do +65°C (Integrator electronics)
-20°C do +80°C (Coil and cable)
Bandwidth (-3dB) 2Hz do 100kHz
Max. Response time (10 to 90%) 1000ms
Accuracy (typ.) ±1.5% of reading (10% to 150% FS, 25°C)
Output load <300Ω
Coil Length 300mm, 500mm or 700mm (Custom lengths available)
Cable Length 1m or 2,5m (Custom lengths available)

Connections
Catalogue number
Current range [A]:
250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000, 10000, 16000, 20000, 25000, 30000, 40000, 50000
Cable Length [m]:
1
2,5
.... Custom lengths available
Coil Length [mm]:
300
500
700
.... Custom lengths available
Options:
BC - option with detachable cable with BNC terminals
Dimensions [mm]

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us

ASK FOR THE PRODUCT close
Message sent successfully.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

The RCTrms is an AC current transducer for permanent installation. Simple to install and easy to retrofit it combines the benefits of a thin, flexible, clip-around Rogowski (sense) coil with a signal conditioner providing accurate, true rms measurement, of AC current. The RCTrms has an industry standard 4-20mA output making it ideal for process control, status alarming or system monitoring purposes. Typically the RCTrms is used with SCADA systems, PLCs, data loggers and protection equipment.

Features:

  • Easy to retrofit
  • Simple to install in applications where space is limited
  • The size of the Rogowski coil can be specified independently of the primary current
  • Does not suffer from magnetic saturation
  • Intrinsically safe
  • Ideal for process control, status alarming or system monitoring in a wide variety of applications, from arc furnaces to power distribution 

Technical data:

  • Traceable calibration
    • Every unit is supplied with a traceable calibration certificate
    • No magnetic materials means excellent linearity <0.2% of reading
  • Fully isolated measurement
    • Isolated power supply 2kVdc
    • Coil rated at 2kVpeak (withstand test is 4kVrms / 50Hz/ 60 sec)
  • Small DIN rail (or panel mount) enclosure – UL94 V-0 rated
 

Options:

  • Isolated BNC-BNC cable split option
    - Between coil and electronics to enable ease of
    installation e.g. threading through existing conduit.
    Standard cable permanently fixed
  • IP65 die-cast aluminium panel mount enclosure
Rated current [Arms] 100, 250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000,10000,16000, 20000, 25000, 40000, 50000
Rated output (Full scale FS)

4 ÷ 20mA

Output limit 150% FS (28mA)
Supply voltage (Wide input) 12Vdc (-10%) to 24Vdc (+20%)
Input power 0.7W (at rated output)
Operating temperature range -5°C do +65°C (Integrator electronics)
-20°C do +80°C (Coil and cable)
Bandwidth (-3dB) 2Hz do 100kHz
Max. Response time (10 to 90%) 1000ms
Accuracy (typ.) ±1.5% of reading (10% to 150% FS, 25°C)
Output load <300Ω
Coil Length 300mm, 500mm or 700mm (Custom lengths available)
Cable Length 1m or 2,5m (Custom lengths available)

Connections
Catalogue number
Current range [A]:
250, 500, 800, 1000, 1600, 2000, 2500, 3000, 4000, 5000, 8000, 10000, 16000, 20000, 25000, 30000, 40000, 50000
Cable Length [m]:
1
2,5
.... Custom lengths available
Coil Length [mm]:
300
500
700
.... Custom lengths available
Options:
BC - option with detachable cable with BNC terminals
Dimensions [mm]