• Connect serial devices to Ethernet • Direct IP, virtual COM port, or paired mode • Ethernet pass-through port available • Fiber Ethernet connectivity options • Serial MEI [Message Exchange Interface] ports Description VLINX™ VESR 9xx industrial serial Ethernet servers allow you to gain control of network devices. If the device has a serial port, it can be monitored and controlled from anywhere on an Ethernet LAN or WAN. You can configure your device to run at peak performance without leaving your office. Troubleshooting can also be done from outside your local network, via the internet. The easy-to-use Vlinx™ Manager software gives you access to your entire facility without leaving your office. This includes device configuration, firmware updates, and device performance monitoring. Configuration changes can also be made via a browser or TELNET console. A range of fiber optic options allows for quick integration with existing networks. There's no need to purchase an additional media converter when you can choose from multimode SC/ST, 15km singlemode SC/ST, 40km singlemode SC/ST, or 80km singlemode SC/ST. VESR92x series servers also feature an additional RJ45 port with twisted copper wire, allowing you to connect another Ethernet device or PC workstation. This pass-through port functions largely like a switch without management features. The test signal keeps the serial connection server connected to the network. If communication is lost, this feature will attempt to reconnect every five seconds until communication is restored. It is not necessary to manually reboot the device once communication is restored. |
Ordering Information Vlinx Serial Server: See the above marking scheme. |
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Software
Vlix Manager: Support for Windows 2000, 2003 Server, XP and Vista
|
Application Example
Direct IP Connection Mode Allows applications using TCP/IP or UDP/IP sockets to communicate directly with devices. ![]() Pairing Allows serial devices to communicate with each other by tunneling signals over the network. ![]() Virtual COM Mode Allows a PC to communicate with serial devices over the network as if they were connected to a physical COM port on the PC. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Are you interested in this product? Do you need additional information or individual pricing?
|
Features
• Connect serial devices to Ethernet • Direct IP, virtual COM port, or paired mode • Ethernet pass-through port available • Fiber Ethernet connectivity options • Serial MEI [Message Exchange Interface] ports Description VLINX™ VESR 9xx industrial serial Ethernet servers allow you to gain control of network devices. If the device has a serial port, it can be monitored and controlled from anywhere on an Ethernet LAN or WAN. You can configure your device to run at peak performance without leaving your office. Troubleshooting can also be done from outside your local network, via the internet. The easy-to-use Vlinx™ Manager software gives you access to your entire facility without leaving your office. This includes device configuration, firmware updates, and device performance monitoring. Configuration changes can also be made via a browser or TELNET console. A range of fiber optic options allows for quick integration with existing networks. There's no need to purchase an additional media converter when you can choose from multimode SC/ST, 15km singlemode SC/ST, 40km singlemode SC/ST, or 80km singlemode SC/ST. VESR92x series servers also feature an additional RJ45 port with twisted copper wire, allowing you to connect another Ethernet device or PC workstation. This pass-through port functions largely like a switch without management features. The test signal keeps the serial connection server connected to the network. If communication is lost, this feature will attempt to reconnect every five seconds until communication is restored. It is not necessary to manually reboot the device once communication is restored. |
Ordering Information Vlinx Serial Server: See the above marking scheme. |
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Software
Vlix Manager: Support for Windows 2000, 2003 Server, XP and Vista
|
Application Example
Direct IP Connection Mode Allows applications using TCP/IP or UDP/IP sockets to communicate directly with devices. ![]() Pairing Allows serial devices to communicate with each other by tunneling signals over the network. ![]() Virtual COM Mode Allows a PC to communicate with serial devices over the network as if they were connected to a physical COM port on the PC. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent