Category
Photos are for informational purposes only. View product specification
please use latin characters
The PCRF-80P0 Conducted Susceptibility Test Generator (CS) is a comprehensive test system designed for testing immunity to conducted and radiated interference. With various module configurations, the device meets the requirements of the IEC61000-4-6 standard (Electromagnetic compatibility – Part 4: Testing and measurement methods – Part 6: Test of immunity to conducted interference induced by high-frequency electromagnetic fields).
This system is used to assess the reliability and stability of electronic devices in an environment of conducted interference. It helps detect device immunity to external interference sources (such as power lines, communication cables, etc.) and provides data and results crucial for engineering design and design improvements.
Parameter | Value |
---|---|
Voltage Output | 1 ~ 30Vrms (CDN method) 1 ~ 18Vrms (electromagnetic clamp method) |
Test Levels | 1V, 3V, 10V, X (custom) |
Output Impedance | 50Ω |
VSWR (Standing Wave Ratio) | ≤1.2 |
Frequency Range | 9kHz ~ 3GHz |
Step Mode | Linear Step (0.1 ~ 100MHz) Proportional Step (0.2 ~ 10%) |
Dwell Time | 0.5s ~ 60s |
Power | -60dBm ~ 10dBm |
Unmodulated Signal | Continuous Wave with Constant Amplitude |
Modulation Mode | Amplitude Modulation: 1Hz ~ 100kHz, Depth: 1 ~ 100% Pulse Modulation: 1Hz ~ 100kHz, Duty Cycle: 1 ~ 100% |
Input Power | -25dBm ~ +20dBm |
Maximum Output Power | +49dBm / 80W |
Harmonic Distortion | ≤30 dBc / <15 dBc |
Output Interface | Type N (socket female) |
Display | 10.1 inches |
Power Supply | AC 220V ±10%, 50/60Hz |
Ambient Temperature | 5°C ~ 35°C |
Ambient Humidity | 45% ~ 75% |
Atmospheric pressure | 86kPa ~ 106kPa |
Power consumption | 200W |
Dimensions | 450 × 222 × 550 mm |
Weight | 30 kg |
Operation Status Indicator | Front Panel LEDs |
Are you interested in this product? Do you need additional information or individual pricing?
The PCRF-80P0 Conducted Susceptibility Test Generator (CS) is a comprehensive test system designed for testing immunity to conducted and radiated interference. With various module configurations, the device meets the requirements of the IEC61000-4-6 standard (Electromagnetic compatibility – Part 4: Testing and measurement methods – Part 6: Test of immunity to conducted interference induced by high-frequency electromagnetic fields).
This system is used to assess the reliability and stability of electronic devices in an environment of conducted interference. It helps detect device immunity to external interference sources (such as power lines, communication cables, etc.) and provides data and results crucial for engineering design and design improvements.
Parameter | Value |
---|---|
Voltage Output | 1 ~ 30Vrms (CDN method) 1 ~ 18Vrms (electromagnetic clamp method) |
Test Levels | 1V, 3V, 10V, X (custom) |
Output Impedance | 50Ω |
VSWR (Standing Wave Ratio) | ≤1.2 |
Frequency Range | 9kHz ~ 3GHz |
Step Mode | Linear Step (0.1 ~ 100MHz) Proportional Step (0.2 ~ 10%) |
Dwell Time | 0.5s ~ 60s |
Power | -60dBm ~ 10dBm |
Unmodulated Signal | Continuous Wave with Constant Amplitude |
Modulation Mode | Amplitude Modulation: 1Hz ~ 100kHz, Depth: 1 ~ 100% Pulse Modulation: 1Hz ~ 100kHz, Duty Cycle: 1 ~ 100% |
Input Power | -25dBm ~ +20dBm |
Maximum Output Power | +49dBm / 80W |
Harmonic Distortion | ≤30 dBc / <15 dBc |
Output Interface | Type N (socket female) |
Display | 10.1 inches |
Power Supply | AC 220V ±10%, 50/60Hz |
Ambient Temperature | 5°C ~ 35°C |
Ambient Humidity | 45% ~ 75% |
Atmospheric pressure | 86kPa ~ 106kPa |
Power consumption | 200W |
Dimensions | 450 × 222 × 550 mm |
Weight | 30 kg |
Operation Status Indicator | Front Panel LEDs |
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent