PTVS-01T0 surge simulator
PTVS-01T0 surge simulator

Photos are for informational purposes only. View product specification

please use latin characters

Manufacturer: EMC Prima

PTVS-01T0 surge simulator

  • PTVS-01T0

PTVS-10T0 has been specifically designed with electromagnetic compatibility requirements in mind – surge (impulse) immunity test (SUG). Used to evaluate the performance of power lines and internal electrical and electronic equipment connections when exposed to high-energy transients caused by switching circuits or lightning strikes.

Features:

  • Ergonomic design
  • 10.1-inch color touchscreen
  • Freely reversible positive and negative polarity
  • Switchable between Chinese and English languages
  • Custom, enhanced, and standard modes
  • Superior technology, durable
  • Maximum test voltage up to 1 kV

Standard compliance:

  • IEC/EN60664
  • GB/T17626.5 / IEC61000-4-5
  • ITU K20
  • ANSI C62.41/45
  • GB/T16927.1
  • IEC/EN 61643-1
  • ITU K44
  • IEC/EN 61010

Parameters:

Parameter Value
Model PTVS-10T0
Open Circuit Voltage 1.0V ~ +1000.0V £10%
Rise Time (1) 1.2µs £30%
Duration (1) 50µs ±20%
Short Circuit Current 0.5A ~ ±500.0A ±10%
Rise Time (2) 8µs ±20%
Duration (2) 20µs ±20%
Polarity +, –, +/–, –/+
Output Impedance 2Ω, 12Ω, 42Ω ±10%
Voltage Step 0V ~ 1000.0V
Pulse Interval 3s ~ 9999s
Pulse Count 1c ~ 6000c
Trigger Mode Manual, External, Interval
Pulse Output Surge Out
Coupling Modes Surge Pulse Output
Capacitor/Inductor Capacitor/Diode
Diode/Diode Diode/Coil
Coupling Network Umax DC 100V, Imax 5A

Send an inquiry

Are you interested in this product? Do you need additional information or individual pricing?

Contact us
ASK FOR THE PRODUCT close
Thank you for sending your message. We will respond as soon as possible.
ASK FOR THE PRODUCT close
Browse

Add to Wishlist

You must be logged in

PTVS-10T0 has been specifically designed with electromagnetic compatibility requirements in mind – surge (impulse) immunity test (SUG). Used to evaluate the performance of power lines and internal electrical and electronic equipment connections when exposed to high-energy transients caused by switching circuits or lightning strikes.

Features:

  • Ergonomic design
  • 10.1-inch color touchscreen
  • Freely reversible positive and negative polarity
  • Switchable between Chinese and English languages
  • Custom, enhanced, and standard modes
  • Superior technology, durable
  • Maximum test voltage up to 1 kV

Standard compliance:

  • IEC/EN60664
  • GB/T17626.5 / IEC61000-4-5
  • ITU K20
  • ANSI C62.41/45
  • GB/T16927.1
  • IEC/EN 61643-1
  • ITU K44
  • IEC/EN 61010

Parameters:

Parameter Value
Model PTVS-10T0
Open Circuit Voltage 1.0V ~ +1000.0V £10%
Rise Time (1) 1.2µs £30%
Duration (1) 50µs ±20%
Short Circuit Current 0.5A ~ ±500.0A ±10%
Rise Time (2) 8µs ±20%
Duration (2) 20µs ±20%
Polarity +, –, +/–, –/+
Output Impedance 2Ω, 12Ω, 42Ω ±10%
Voltage Step 0V ~ 1000.0V
Pulse Interval 3s ~ 9999s
Pulse Count 1c ~ 6000c
Trigger Mode Manual, External, Interval
Pulse Output Surge Out
Coupling Modes Surge Pulse Output
Capacitor/Inductor Capacitor/Diode
Diode/Diode Diode/Coil
Coupling Network Umax DC 100V, Imax 5A
Comments (0)