The PEFT-CDN-3100/3200-690 model is a high-voltage, high-current EFT pulse group coupling/decoupling network designed for AC/DC power pulse group testing. Allows automatic three-phase coupling and decoupling.
The maximum load on the EUT (device under test) is:
Other voltage and current values can be customized to customer requirements.
Parameter | Value / Description |
---|---|
Output voltage range | 200V ~ 5000V ±10% |
Voltage Resolution | 1V |
Voltage Surge | 1V |
Voltage Accuracy | < ±10% |
Output Polarity | +, -, +/-, -/+ |
T&H | Built-in Thermometer and Humidity Meter |
Source Impedance | 50Ω |
Pulse Rise Time | 5ns ±30% |
Pulse duration | 50ns ±30% (50Ω load) 35ns ~ 150ns (1000Ω load) |
Frequency range | 0.1kHz ~ 1200kHz |
Frequency resolution | 0.1kHz |
Standard Frequencies | 5kHz, 100kHz |
Pulse Group Duration | 0.001 ~ 2550.000 ms |
Pulse Group Period | 300 ms (0.15 ~ 99.99 s) |
Test Duration | 1s ~ 9999s |
Direct Output Mode | Via Coaxial High Voltage Connector |
Phase Sync | 0° ~ 359° (for 45 Hz ~ 65 Hz) (synchronous, automatic, asynchronous) |
Coupling | Built-in 3-phase, 5-wire coupling |
Load capacity | UAC MAX 690V / 200A UDC MAX 1000V / 200A |
Are you interested in this product? Do you need additional information or individual pricing?
The PEFT-CDN-3100/3200-690 model is a high-voltage, high-current EFT pulse group coupling/decoupling network designed for AC/DC power pulse group testing. Allows automatic three-phase coupling and decoupling.
The maximum load on the EUT (device under test) is:
Other voltage and current values can be customized to customer requirements.
Parameter | Value / Description |
---|---|
Output voltage range | 200V ~ 5000V ±10% |
Voltage Resolution | 1V |
Voltage Surge | 1V |
Voltage Accuracy | < ±10% |
Output Polarity | +, -, +/-, -/+ |
T&H | Built-in Thermometer and Humidity Meter |
Source Impedance | 50Ω |
Pulse Rise Time | 5ns ±30% |
Pulse duration | 50ns ±30% (50Ω load) 35ns ~ 150ns (1000Ω load) |
Frequency range | 0.1kHz ~ 1200kHz |
Frequency resolution | 0.1kHz |
Standard Frequencies | 5kHz, 100kHz |
Pulse Group Duration | 0.001 ~ 2550.000 ms |
Pulse Group Period | 300 ms (0.15 ~ 99.99 s) |
Test Duration | 1s ~ 9999s |
Direct Output Mode | Via Coaxial High Voltage Connector |
Phase Sync | 0° ~ 359° (for 45 Hz ~ 65 Hz) (synchronous, automatic, asynchronous) |
Coupling | Built-in 3-phase, 5-wire coupling |
Load capacity | UAC MAX 690V / 200A UDC MAX 1000V / 200A |